Comparative evaluation of pre-column derivatization strategies for PFAS analysis in paper-based food contact material using GC-MS

The analysis of paper-based food contact materials (FCM) has gained increasing attention due to the widespread use of per- and polyfluoroalkyl substances (PFAS) and their known toxic effects and environmental persistence. As regulatory frameworks for PFAS in FCM remain limited, sensitive and reliable analytical methods are necessary to ensure food safety. While PFAS analysis is predominantly performed using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), a systematic development of gas chromatography coupled to mass spectrometry (GC-MS)-based methods for multiple PFAS classes remains limited. In this study, two pre-column derivatization techniques were optimized and evaluated for GC-MS determination of perfluoroalkyl carboxylic acids (PFCA), fluorotelomer alcohols (FTOH), and fluorotelomer carboxylic acids (FTCA). Both derivatization methods enabled qualification and quantification of the targeted PFAS with comparable limits of detection in the low ng/mL range. N,N-Dimethylformamide dimethyl acetal (DMFDMA) derivatization proved to be more sensitive with a limit of detection down to 0.85 ng/mL. In addition, this derivatization approach was successfully automated within the GC-MS workflow, resulting in sample preparation times comparable to those of LC-MS-based methods. The application of this optimized method to paper-based FCM demonstrated its suitability for real world FCM analysis. Results of PFAS content per targeted PFAS of 26.6 to 261.4 ng/g highlight the potential of GC-MS analysis, particularly when combined with automated derivatization, as a viable alternative or complement to LC-MS for PFAS analysis in FCM.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2026-07-25
DOI
https://doi.org/10.1007/s00216-026-06683-z
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of pre-column derivatization strategies for PFAS analysis in paper-based food contact material using GC-MS

Hajo Haase, Christian Jung, Roland Becker, Charlotte Hauschildt
Analytical and Bioanalytical Chemistry
Analytical chemistry methods development
article

Comparative evaluation of pre-column derivatization strategies for PFAS analysis in paper-based food contact material using GC-MS

Hajo Haase, Christian Jung, Roland Becker, Charlotte Hauschildt
article en

Abstract

The analysis of paper-based food contact materials (FCM) has gained increasing attention due to the widespread use of per- and polyfluoroalkyl substances (PFAS) and their known toxic effects and environmental persistence. As regulatory frameworks for PFAS in FCM remain limited, sensitive and reliable analytical methods are necessary to ensure food safety. While PFAS analysis is predominantly performed using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), a systematic development of gas chromatography coupled to mass spectrometry (GC-MS)-based methods for multiple PFAS classes remains limited. In this study, two pre-column derivatization techniques were optimized and evaluated for GC-MS determination of perfluoroalkyl carboxylic acids (PFCA), fluorotelomer alcohols (FTOH), and fluorotelomer carboxylic acids (FTCA). Both derivatization methods enabled qualification and quantification of the targeted PFAS with comparable limits of detection in the low ng/mL range. N,N-Dimethylformamide dimethyl acetal (DMFDMA) derivatization proved to be more sensitive with a limit of detection down to 0.85 ng/mL. In addition, this derivatization approach was successfully automated within the GC-MS workflow, resulting in sample preparation times comparable to those of LC-MS-based methods. The application of this optimized method to paper-based FCM demonstrated its suitability for real world FCM analysis. Results of PFAS content per targeted PFAS of 26.6 to 261.4 ng/g highlight the potential of GC-MS analysis, particularly when combined with automated derivatization, as a viable alternative or complement to LC-MS for PFAS analysis in FCM.

Analytical and Bioanalytical Chemistry
Federal Institute For Materials Research and Testing (DE), Technische Universität Berlin (DE)
European Partnership on Metrology, European Commission, HORIZON EUROPE Framework Programme
Zero hunger
Openalex Percentile: Top 12%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.