MOUSE MODEL VALIDATION OF A SHORTENED NON-EQUILIBRATION BLASTOCYST VITRIFICATION PROTOCOL DEMONSTRATES COMPATIBILITY WITH OPEN AND CLOSED VITRIFICATION DEVICES
OBJECTIVE: To assess the impact of vitrification device – open or closed – on embryological outcomes in mouse blastocysts vitrified using a non-equilibration protocol. DESIGN: Experimental mouse study. MATERIALS AND METHODS: B6C3F1 hybrid mice were super‑ovulated with PMSG and hCG, mated, and 1‑cell embryos collected 18–20 hours later. Eight experimental groups (n=75 blastocysts/group) were established using combinations of traditional (S) or non‑equilibration (F) vitrification, multi‑step (S) or single‑step (F) warming, and open (O) or closed (C) vitrification devices (VitriGuard™/VitriFit™, CooperSurgical, USA). All procedures were conducted using SAGE™ vitrification and warming kits. Group S/S represented the current standard‑of‑care control. Embryos were cultured in global™ total™ medium (CooperSurgical, USA) and assessed for morphology and expansion at 2 and 24 hours post‑warming. Total and apoptotic cell counts were evaluated using Hoechst 33342 and TUNEL staining. Statistical analysis was performed using Fisher’s exact and t-tests. RESULTS: Overall blastocyst survival was 99.3% (596/600), 99.0% in the open device and 99.7% in the closed device, with no significant differences between open and closed devices, between protocol combinations, or compared with standard of care (p>0.05). At 24 hours, all surviving blastocysts were expanded or hatching, with no device‑related differences. Apoptotic cell counts were comparable between devices in most groups; however, in the S/F group, closed devices demonstrated lower apoptotic cell counts compared with open devices (5.44±2.65 vs 7.39±1.89, p<0.001). CONCLUSIONS: These data demonstrate that short non‑equilibration vitrification protocols are compatible with both open and closed vitrification systems, supporting workflow efficiencies without compromising embryological outcomes. Further investigation is warranted to confirm findings related to apoptotic cell differences. Support: Study was conducted by CooperSurgical employees and within CooperSurgical facilities.
Authors
- R Vassena
- J Rodriquez Quesada
- P Damiani
- C Lynch
- A Giovannini
Institutions
- Cooper University Hospital (US)
- Cooper Clinic (US)
- Cooper and Company (United States) (US)
- Cooper Clinic (US)
Publication Details
- Journal
- North American Proceedings in Gynecology and Obstetrics - Supplemental
- Published
- 2026-07-25
- DOI
- https://doi.org/10.54053/001c.165361
- Primary Topic
- Reproductive Biology and Fertility
- Type
- article
- Field-Weighted Citation Impact
- 0.00