Position‐Independent Particle Sizing in High‐Precision Impedance Cytometry via Full‐Waveform Feature Calibration

ABSTRACT Accurate particle characterization is critical for biomedical research, yet electrical impedance flow cytometry suffers from measurement inaccuracies due to the positional heterogeneity of particles within microfluidic channels. In large‐scale microchannels, off‐axis particle trajectories lead to significant waveform distortion and the attenuation of key characteristic features, undermining measurement precision. To address this issue, this study presents a novel signal‐processing framework centered on a full‐waveform calibration factor (CF). The CF is theoretically grounded in the exponential decay of the electric field along the vertical axis of coplanar electrodes and is derived from comprehensive waveform features rather than localized extrema, ensuring robustness against the distortions prevalent in high‐flow conditions. Coupled with a dedicated real‐time algorithm, it corrects for vertical position‐induced errors in particle sizing. The effectiveness of this method was validated through a combination of finite element simulation and experimental impedance measurement. The system's performance is demonstrated by accurately discriminating polystyrene microsphere populations (10 , 15 , and their mixture) and by resolving the size distributions of viable versus non‐viable HEK‐293T cells. Statistical analysis ( events per group, ) confirms significant improvement in size‐distribution accuracy after calibration. Furthermore, this study designs an inverted microfluidic chip enabling real‐time, optical sensing of particle stream height within the impedance detection zone and supporting position‐independent impedance cytometry applicable to continuous‐flow particle streams. Experimental calibration achieves a strong linear correlation () between the sensor response and measured height, confirming the method's utility for spatially resolved impedance cytometry.

Authors

Institutions

Publication Details

Journal
Electrophoresis
Published
2026-07-24
DOI
https://doi.org/10.1002/elps.70132
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Position‐Independent Particle Sizing in High‐Precision Impedance Cytometry via Full‐Waveform Feature Calibration

Hepeng Zhou, Wenjie Yang, Tanbin Su, Shanshan Li et al.
Electrophoresis
Microfluidic and Bio-sensing Technologies
article

Position‐Independent Particle Sizing in High‐Precision Impedance Cytometry via Full‐Waveform Feature Calibration

Hepeng Zhou, Wenjie Yang, Tanbin Su, Shanshan Li, Junwei Li, J R Wu, Shengran Pan
article en

Abstract

ABSTRACT Accurate particle characterization is critical for biomedical research, yet electrical impedance flow cytometry suffers from measurement inaccuracies due to the positional heterogeneity of particles within microfluidic channels. In large‐scale microchannels, off‐axis particle trajectories lead to significant waveform distortion and the attenuation of key characteristic features, undermining measurement precision. To address this issue, this study presents a novel signal‐processing framework centered on a full‐waveform calibration factor (CF). The CF is theoretically grounded in the exponential decay of the electric field along the vertical axis of coplanar electrodes and is derived from comprehensive waveform features rather than localized extrema, ensuring robustness against the distortions prevalent in high‐flow conditions. Coupled with a dedicated real‐time algorithm, it corrects for vertical position‐induced errors in particle sizing. The effectiveness of this method was validated through a combination of finite element simulation and experimental impedance measurement. The system's performance is demonstrated by accurately discriminating polystyrene microsphere populations (10 , 15 , and their mixture) and by resolving the size distributions of viable versus non‐viable HEK‐293T cells. Statistical analysis ( events per group, ) confirms significant improvement in size‐distribution accuracy after calibration. Furthermore, this study designs an inverted microfluidic chip enabling real‐time, optical sensing of particle stream height within the impedance detection zone and supporting position‐independent impedance cytometry applicable to continuous‐flow particle streams. Experimental calibration achieves a strong linear correlation () between the sensor response and measured height, confirming the method's utility for spatially resolved impedance cytometry.

Electrophoresis
Hebei University of Technology (CN), University of Tennessee at Knoxville (US)
National Natural Science Foundation of China, Natural Science Foundation of Hebei Province, Tianjin Science and Technology Program
Reduced inequalities
Openalex Percentile: Top 16%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.