Ultra-widefield color fundus images and artificial intelligence for diagnosis of diabetic retinopathy: A systematic review and meta-analysis

PURPOSE: Ultra-widefield (UWF) fundus cameras capture a larger retinal area without pupil dilation. We summarized evidence and diagnostic performance of artificial intelligence (AI)-driven diabetic retinopathy (DR) assessments using UWF images (UWFIs). METHODS: We searched PubMed, Scopus, the Cochrane Library, and Web of Science to February 9, 2025, for studies evaluating DR using UWFIs and AI analyses. We followed the PRISMA guidelines and assessed study quality using the Joanna Briggs Institute Critical Appraisal Checklist for diagnostic accuracy. Forest plots and summary receiver operating characteristic curves estimated sensitivity and specificity of AI-driven DR screening using UWFI. RESULTS: Of 527 records identified, 17 studies were included in the systematic review and four in the meta-analysis. All studies used Optos software. Among the included studies, two evaluated DR discrimination from multiple retinal disorders, six addressed DR stage classification based on guideline scales, six evaluated DR screening, and one each focused on referable retinal pathology detection, DR progression prediction, and detection of clinical DR features. The summary sensitivity, specificity, and area under receiver operating characteristic curve for AI-driven DR screening using UWFI were 85.0%, 72.5%, and 0.870 (0.838-0.897), respectively. UWFI-based AI screening showed acceptable sensitivity but limited specificity. CONCLUSION: AI-driven DR screening using UWFIs may achieve acceptable sensitivity but with limited specificity; however, these findings should be interpreted with caution, given the limited number of available studies. Further studies using larger, diverse datasets with rigorous external validation across UWF platforms are needed to improve generalizability and clarify the clinical role of UWFI-based AI.

Authors

Institutions

Publication Details

Journal
Retina
Published
2026-07-24
DOI
https://doi.org/10.1097/iae.0000000000004939
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-widefield color fundus images and artificial intelligence for diagnosis of diabetic retinopathy: A systematic review and meta-analysis

Ken Nagino, Takenori Inomata, Shintaro Nakao, Kenta Fujio et al.
Retina
Retinal Imaging and Analysis
article

Ultra-widefield color fundus images and artificial intelligence for diagnosis of diabetic retinopathy: A systematic review and meta-analysis

Ken Nagino, Takenori Inomata, Shintaro Nakao, Kenta Fujio, Hiroyuki Kobayashi, Atsuko Eguchi, Jaemyoung Sung, Kunihiko Hirosawa, Akie Midorikawa-Inomata
article en

Abstract

PURPOSE: Ultra-widefield (UWF) fundus cameras capture a larger retinal area without pupil dilation. We summarized evidence and diagnostic performance of artificial intelligence (AI)-driven diabetic retinopathy (DR) assessments using UWF images (UWFIs). METHODS: We searched PubMed, Scopus, the Cochrane Library, and Web of Science to February 9, 2025, for studies evaluating DR using UWFIs and AI analyses. We followed the PRISMA guidelines and assessed study quality using the Joanna Briggs Institute Critical Appraisal Checklist for diagnostic accuracy. Forest plots and summary receiver operating characteristic curves estimated sensitivity and specificity of AI-driven DR screening using UWFI. RESULTS: Of 527 records identified, 17 studies were included in the systematic review and four in the meta-analysis. All studies used Optos software. Among the included studies, two evaluated DR discrimination from multiple retinal disorders, six addressed DR stage classification based on guideline scales, six evaluated DR screening, and one each focused on referable retinal pathology detection, DR progression prediction, and detection of clinical DR features. The summary sensitivity, specificity, and area under receiver operating characteristic curve for AI-driven DR screening using UWFI were 85.0%, 72.5%, and 0.870 (0.838-0.897), respectively. UWFI-based AI screening showed acceptable sensitivity but limited specificity. CONCLUSION: AI-driven DR screening using UWFIs may achieve acceptable sensitivity but with limited specificity; however, these findings should be interpreted with caution, given the limited number of available studies. Further studies using larger, diverse datasets with rigorous external validation across UWF platforms are needed to improve generalizability and clarify the clinical role of UWFI-based AI.

Retina
Juntendo University (JP), Juntendo University Hospital (JP)
Peace, Justice and strong institutions, Reduced inequalities
Openalex Percentile: Top 8%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.