A Hybrid VMD-SVM Multi-Feature and Wavelet Modulus Maxima-Based Method for Fault Line Identification and Location in Distribution Networks with Single-Phase Ground Faults

Introduction/Objective: The transition from traditional power grids to new-type power systems increases the complexity of distribution networks, making fault currents weaker, more volatile, and richer in harmonics. To address the challenges of accurate identification, line selection, and location of single-phase ground faults in small-current grounding systems, an integrated method is proposed. Methods: A fault type identification step is incorporated prior to line selection and location. Sequence component characteristics are first used to identify the fault type. Multiple fault features are then constructed based on Variational Mode Decomposition (VMD) adaptively optimized by the Sparrow Search Algorithm (SSA). The Support Vector Machine (SVM) algorithm fuses these features for accurate fault line selection. Subsequently, the faulty phase is determined by analyzing the line-mode component characteristics of the selected fault line. Finally, a single-ended fault location method based on wavelet transform modulus maxima is applied to pinpoint the fault. A distribution network fault simulation model is established in Matlab/Simulink. Results: Simulation results show that the proposed method achieves a fault-line selection accuracy of 98.4%, and the location error for a 100 km line is less than 1.673% Discussion: The obtained accuracy and location precision demonstrate the effectiveness of the proposed VMD-SVM multi-feature fusion combined with wavelet modulus maxima ranging. Compared with conventional fuzzy theory methods, the SVM-based approach shows superior performance under limited sample conditions and complex fault scenarios. Conclusion: The proposed method effectively enhances the accuracy and reliability of single- phase ground-fault processing, offering a feasible technical solution for rapid isolation and precise location of faults in distribution networks.

Authors

Institutions

Publication Details

Journal
Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
Published
2026-07-23
DOI
https://doi.org/10.2174/0123520965482463260708100410
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Hybrid VMD-SVM Multi-Feature and Wavelet Modulus Maxima-Based Method for Fault Line Identification and Location in Distribution Networks with Single-Phase Ground Faults

Le Dong, Jingshan Mo, X F Li, Rui Zhao et al.
Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
Power Systems Fault Detection
article

A Hybrid VMD-SVM Multi-Feature and Wavelet Modulus Maxima-Based Method for Fault Line Identification and Location in Distribution Networks with Single-Phase Ground Faults

Le Dong, Jingshan Mo, X F Li, Rui Zhao, Shuang He
article en

Abstract

Introduction/Objective: The transition from traditional power grids to new-type power systems increases the complexity of distribution networks, making fault currents weaker, more volatile, and richer in harmonics. To address the challenges of accurate identification, line selection, and location of single-phase ground faults in small-current grounding systems, an integrated method is proposed. Methods: A fault type identification step is incorporated prior to line selection and location. Sequence component characteristics are first used to identify the fault type. Multiple fault features are then constructed based on Variational Mode Decomposition (VMD) adaptively optimized by the Sparrow Search Algorithm (SSA). The Support Vector Machine (SVM) algorithm fuses these features for accurate fault line selection. Subsequently, the faulty phase is determined by analyzing the line-mode component characteristics of the selected fault line. Finally, a single-ended fault location method based on wavelet transform modulus maxima is applied to pinpoint the fault. A distribution network fault simulation model is established in Matlab/Simulink. Results: Simulation results show that the proposed method achieves a fault-line selection accuracy of 98.4%, and the location error for a 100 km line is less than 1.673% Discussion: The obtained accuracy and location precision demonstrate the effectiveness of the proposed VMD-SVM multi-feature fusion combined with wavelet modulus maxima ranging. Compared with conventional fuzzy theory methods, the SVM-based approach shows superior performance under limited sample conditions and complex fault scenarios. Conclusion: The proposed method effectively enhances the accuracy and reliability of single- phase ground-fault processing, offering a feasible technical solution for rapid isolation and precise location of faults in distribution networks.

Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)Vol. 19
Northeast Electric Power University (CN)
Openalex Percentile: Top 10%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.