Two‐phase ammonia plume behavior in a still room: Jack Rabbit <scp>III</scp> chamber studies
Abstract This paper describes a new set of 45 laboratory experiments where about 180 g of ammonia was released from pressurized liquefied storage in a still 51.3 m 3 chamber (i.e., a small room) and the variations of the ammonia gas concentrations and liquid deposition over a 60 min time period were investigated. Chamber temperatures ranged from −18 to 40°C, and relative humidities from 11% to 90%. A liquid collection (catch) tray was placed so that the 45° downwards‐directed two‐phase jet would strike its center, and a scale under the tray measured the liquid mass. In three trials, the tray was inverted; in six trials, a water spray system was operated; and, in four trials, CO 2 gas was introduced. The initial ammonia deposition to the tray ranged from about 10%–50% of the released mass, with the larger fractions occurring during colder conditions. The strong ammonia jet generated eddies lasting for many minutes. The addition of CO 2 gas produced only minor differences in the concentrations. The addition of water spray resulted in about a 50% reduction in ammonia vapor. These results should be helpful in planning emergency response to ammonia accidents in confined locations.
Authors
- Steven R. Hanna (ORCID: https://orcid.org/0000-0003-3966-4771)
- Sun McMasters
- Ronald Meris
Institutions
- United States Department of Homeland Security (US)
- Defense Threat Reduction Agency (US)
- CECOM Software Engineering Center (US)
Publication Details
- Journal
- Process Safety Progress
- Published
- 2026-07-24
- DOI
- https://doi.org/10.1002/prs.70050
- Primary Topic
- Fire dynamics and safety research
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- U.S. Department of Homeland Security
- Transport Canada
- Defense Threat Reduction Agency