Analysis of the Frequency-Dependent Sensitivity Distribution for Lower Forearm Impedance Plethysmography

OBJECTIVE: The assessment of hemodynamic parameters plays an important role for the diagnosis and detection of cardiovascular diseases. One of the promising techniques for the non-invasive and continuous monitoring of arterial hemodynamics is the impedance
plethysmography (IPG), which aims to measure the pulsatile volume change of superficial arteries. Crucial for the success of an IPG measurement is the selection of a setup that effectively targets the artery. APPROACH: This work analyzes the influence of the injection
frequency alteration on the sensitivity distribution of an IPG measurement and the sensitivity towards the radial artery. The analysis is performed both in simulation and using study data obtained from 41 participants. The simulation consists of a finite element model representing the lower forearm and a fixed IPG setup, in which the sensitivity distribution is analyzed for different excitation frequencies between 3 kHz and 100 kHz. To allow for comparison, the IPG study utilizes the same five excitation frequencies between 3 kHz and 100 kHz. MAIN RESULTS: The results of the finite element simulation show that increasing excitation frequency shifts the region of large sensitivity away from the artery and especially towards deeper muscle tissue layers. The analysis of the study data supports
this hypothesis by demonstrating that lower-frequency excitation yields larger relative pulsatile changes than larger excitation frequencies, thus indicating a larger sensitivity towards the pulsatile artery. SIGNIFICANCE: The results of this paper show, that injection frequency directly affects the sensitivity regions. Analysis of the FEM and study results indicate that the largest sensitivity towards the radial artery occurs at the smallest injection frequency. Thus, comparison of IPG measurements performed at different excitation frequencies should be interpreted carefully, comparability between individual measurements may be limited.

Authors

Institutions

Publication Details

Journal
Physiological Measurement
Published
2026-07-24
DOI
https://doi.org/10.1088/1361-6579/ae9035
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Frequency-Dependent Sensitivity Distribution for Lower Forearm Impedance Plethysmography

Christian Wiede, Roman Kusche, Karsten Seidl, Niko Strotmann
Physiological Measurement
Hemodynamic Monitoring and Therapy
article

Analysis of the Frequency-Dependent Sensitivity Distribution for Lower Forearm Impedance Plethysmography

Christian Wiede, Roman Kusche, Karsten Seidl, Niko Strotmann
article en

Abstract

OBJECTIVE: The assessment of hemodynamic parameters plays an important role for the diagnosis and detection of cardiovascular diseases. One of the promising techniques for the non-invasive and continuous monitoring of arterial hemodynamics is the impedance
plethysmography (IPG), which aims to measure the pulsatile volume change of superficial arteries. Crucial for the success of an IPG measurement is the selection of a setup that effectively targets the artery. APPROACH: This work analyzes the influence of the injection
frequency alteration on the sensitivity distribution of an IPG measurement and the sensitivity towards the radial artery. The analysis is performed both in simulation and using study data obtained from 41 participants. The simulation consists of a finite element model representing the lower forearm and a fixed IPG setup, in which the sensitivity distribution is analyzed for different excitation frequencies between 3 kHz and 100 kHz. To allow for comparison, the IPG study utilizes the same five excitation frequencies between 3 kHz and 100 kHz. MAIN RESULTS: The results of the finite element simulation show that increasing excitation frequency shifts the region of large sensitivity away from the artery and especially towards deeper muscle tissue layers. The analysis of the study data supports
this hypothesis by demonstrating that lower-frequency excitation yields larger relative pulsatile changes than larger excitation frequencies, thus indicating a larger sensitivity towards the pulsatile artery. SIGNIFICANCE: The results of this paper show, that injection frequency directly affects the sensitivity regions. Analysis of the FEM and study results indicate that the largest sensitivity towards the radial artery occurs at the smallest injection frequency. Thus, comparison of IPG measurements performed at different excitation frequencies should be interpreted carefully, comparability between individual measurements may be limited.

Physiological Measurement
Universität Hamburg (DE), Fraunhofer Institute for Microelectronic Circuits and Systems (DE), University of Duisburg-Essen (DE), HAW Hamburg (DE)
Good health and well-being
Openalex Percentile: Top 7%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.