A novel approach to determine the positron emission intensity in the decay of a radionuclide for medical applications: an overview

Abstract With the increasing significance of positron emission tomography in medicine, the need for development of novel positron emitters is increasing. A prerequisite for their use is a precise knowledge of the positron emission intensity in their decay. The literature data are generally based on standardisation of older decay schemes and therefore often lack accuracy. We have developed a new approach of directly measuring the positron emission component through high-resolution γ-ray spectroscopy, beta counting and γγ-coincidence counting, and the electron capture component via high-resolution X-ray spectroscopy. This article provides an overview of the seven radionuclides investigated, namely 45 Ti, 64 Cu, 72 As, 76 Br, 86g Y, 120g I and 124 I. Our results agree with the literature values derived from the extensively investigated decay schemes in recent years, but not with those obtained from poorly characterised older decay schemes. The potentially useful positron emitters that require such studies are briefly outlined.

Authors

Institutions

Publication Details

Journal
Journal of Radioanalytical and Nuclear Chemistry
Published
2026-07-24
DOI
https://doi.org/10.1007/s10967-026-11050-4
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel approach to determine the positron emission intensity in the decay of a radionuclide for medical applications: an overview

Syed M. Qaim, Bernd Neumaier
Journal of Radioanalytical and Nuclear Chemistry
Radioactive Decay and Measurement Techniques
article

A novel approach to determine the positron emission intensity in the decay of a radionuclide for medical applications: an overview

Syed M. Qaim, Bernd Neumaier
article en

Abstract

Abstract With the increasing significance of positron emission tomography in medicine, the need for development of novel positron emitters is increasing. A prerequisite for their use is a precise knowledge of the positron emission intensity in their decay. The literature data are generally based on standardisation of older decay schemes and therefore often lack accuracy. We have developed a new approach of directly measuring the positron emission component through high-resolution γ-ray spectroscopy, beta counting and γγ-coincidence counting, and the electron capture component via high-resolution X-ray spectroscopy. This article provides an overview of the seven radionuclides investigated, namely 45 Ti, 64 Cu, 72 As, 76 Br, 86g Y, 120g I and 124 I. Our results agree with the literature values derived from the extensively investigated decay schemes in recent years, but not with those obtained from poorly characterised older decay schemes. The potentially useful positron emitters that require such studies are briefly outlined.

Journal of Radioanalytical and Nuclear Chemistry
Forschungszentrum Jülich (DE)
Openalex Percentile: Top 9%
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.