Assumed but unverified: Healthcare professionals' experiences of medication delivery reliability in neonatal care – A qualitative focus group study

Background Accurate medication delivery is fundamental to safe neonatal infusion therapy, yet clinicians rarely have direct confirmation that medications are delivered as intended. Consequently, infusion monitoring relies on indirect indicators such as pump-alarms and patient condition, creating uncertainty in routine neonatal practice. Aim To explore the experiences and perceptions of neonatal nurses and related healthcare professionals regarding infusion monitoring and medication delivery reliability in neonatal care. Methods An exploratory qualitative focus group study was conducted using a single focus group involving six Dutch neonatal healthcare professionals experienced in infusion therapy. Data were collected using a semi-structured topic guide and analysed using reflexive thematic analysis. Results Four interrelated themes described how medication delivery was largely assumed rather than verified in routine neonatal care: (1) reactive monitoring as the dominant system pattern, (2) knowledge limitations and educational gaps in infusion practice, (3) organisational and system-level constraints, and (4) consequences for patients and healthcare professionals. Participants described relying on indirect indicators such as pump alarms, visual inspection, and changes in the infant's clinical condition to judge whether therapy was being delivered as intended. Educational and organisational factors, together with limited visibility of medication delivery, reinforced reactive monitoring, contributing to clinical uncertainty, increased workload, and concerns regarding patient safety. Conclusion Neonatal infusion monitoring operates within systems where medication delivery is largely assumed rather than directly verified. Reactive monitoring represents an adaptive response to limited system visibility rather than a deficiency in clinical practice. Improving infusion safety requires a coordinated systems approach that combines education, organisational improvement, and appropriately evaluated technologies that enhance the visibility of medication delivery, supporting a transition from reactive to proactive monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Neonatal Nursing
Published
2026-07-24
DOI
https://doi.org/10.1016/j.jnn.2026.101943
Primary Topic
Patient Safety and Medication Errors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assumed but unverified: Healthcare professionals' experiences of medication delivery reliability in neonatal care – A qualitative focus group study

Tinneke Jonckers, Matheus van Rens, Geja van Blijderveen, Agnes van den Hoogen et al.
Journal of Neonatal Nursing
Patient Safety and Medication Errors
article

Assumed but unverified: Healthcare professionals' experiences of medication delivery reliability in neonatal care – A qualitative focus group study

Tinneke Jonckers, Matheus van Rens, Geja van Blijderveen, Agnes van den Hoogen, Marloes Peters-Zwaan, Iris Borger
article en

Abstract

Background Accurate medication delivery is fundamental to safe neonatal infusion therapy, yet clinicians rarely have direct confirmation that medications are delivered as intended. Consequently, infusion monitoring relies on indirect indicators such as pump-alarms and patient condition, creating uncertainty in routine neonatal practice. Aim To explore the experiences and perceptions of neonatal nurses and related healthcare professionals regarding infusion monitoring and medication delivery reliability in neonatal care. Methods An exploratory qualitative focus group study was conducted using a single focus group involving six Dutch neonatal healthcare professionals experienced in infusion therapy. Data were collected using a semi-structured topic guide and analysed using reflexive thematic analysis. Results Four interrelated themes described how medication delivery was largely assumed rather than verified in routine neonatal care: (1) reactive monitoring as the dominant system pattern, (2) knowledge limitations and educational gaps in infusion practice, (3) organisational and system-level constraints, and (4) consequences for patients and healthcare professionals. Participants described relying on indirect indicators such as pump alarms, visual inspection, and changes in the infant's clinical condition to judge whether therapy was being delivered as intended. Educational and organisational factors, together with limited visibility of medication delivery, reinforced reactive monitoring, contributing to clinical uncertainty, increased workload, and concerns regarding patient safety. Conclusion Neonatal infusion monitoring operates within systems where medication delivery is largely assumed rather than directly verified. Reactive monitoring represents an adaptive response to limited system visibility rather than a deficiency in clinical practice. Improving infusion safety requires a coordinated systems approach that combines education, organisational improvement, and appropriately evaluated technologies that enhance the visibility of medication delivery, supporting a transition from reactive to proactive monitoring.

Journal of Neonatal NursingVol. 32(5)
University Medical Center Groningen (NL), Radboud University Nijmegen (NL), Dialyse Centrum Groningen (NL), Beatrix Kinderziekenhuis (NL), Máxima Medisch Centrum (NL)
Health~Holland
Openalex Percentile: Top 6%
Patient Safety and Medication Errors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.