Delayed Arteriovenous Fistula Maturation Associated With an Ipsilateral Transvenous Implantable Cardioverter Defibrillator (ICD) Lead and Suspected Functional Hemodynamic Obstruction

Arteriovenous fistula (AVF) maturation failure is a possible barrier to establishing permanent hemodialysis access. While overt stenosis is the most commonly cited cause, a substantial proportion of non-maturing fistulas lack angiographically apparent lesions, suggesting that subclinical hemodynamic and geometric factors play a critical role. This case describes a 65-year-old man with end-stage renal disease on hemodialysis, coronary artery disease status post right coronary artery (RCA) stent placement, ischemic cardiomyopathy (left ventricular ejection fraction (LVEF) 40-45%), and a history of sustained ventricular tachycardia requiring single-chamber transvenous implantable cardioverter defibrillator (ICD) placement, who underwent left upper extremity AVF creation ipsilateral to the device. Despite serial fistulograms demonstrating patent central veins without discrete stenosis, the fistula failed to mature over five months. The clinical course and sequential interventions--coil embolization of accessory venous branches, transvenous ICD extraction with subcutaneous ICD placement, and continued surveillance--were followed by clinical improvement and a patent AVF that was cleared for hemodialysis use. The temporal association between lead extraction and subsequent clinical improvement and clearance of the AVF for hemodialysis use is consistent with the hypothesis that the ipsilateral transvenous ICD lead may have contributed to delayed maturation through subclinical flow perturbation rather than overt mechanical stenosis. This case highlights the importance of considering ICD platform selection as a modifiable factor in dialysis access planning and illustrates the value of transitioning from transvenous to subcutaneous ICD to preserve vascular access in dialysis-dependent patients.

Authors

Publication Details

Journal
Cureus
Published
2026-07-24
DOI
https://doi.org/10.7759/cureus.113325
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Delayed Arteriovenous Fistula Maturation Associated With an Ipsilateral Transvenous Implantable Cardioverter Defibrillator (ICD) Lead and Suspected Functional Hemodynamic Obstruction

VICKRAM REDDY, Vivek Reddy, Suhaimi Hussain
Cureus
Central Venous Catheters and Hemodialysis
article

Delayed Arteriovenous Fistula Maturation Associated With an Ipsilateral Transvenous Implantable Cardioverter Defibrillator (ICD) Lead and Suspected Functional Hemodynamic Obstruction

VICKRAM REDDY, Vivek Reddy, Suhaimi Hussain
article en

Abstract

Arteriovenous fistula (AVF) maturation failure is a possible barrier to establishing permanent hemodialysis access. While overt stenosis is the most commonly cited cause, a substantial proportion of non-maturing fistulas lack angiographically apparent lesions, suggesting that subclinical hemodynamic and geometric factors play a critical role. This case describes a 65-year-old man with end-stage renal disease on hemodialysis, coronary artery disease status post right coronary artery (RCA) stent placement, ischemic cardiomyopathy (left ventricular ejection fraction (LVEF) 40-45%), and a history of sustained ventricular tachycardia requiring single-chamber transvenous implantable cardioverter defibrillator (ICD) placement, who underwent left upper extremity AVF creation ipsilateral to the device. Despite serial fistulograms demonstrating patent central veins without discrete stenosis, the fistula failed to mature over five months. The clinical course and sequential interventions--coil embolization of accessory venous branches, transvenous ICD extraction with subcutaneous ICD placement, and continued surveillance--were followed by clinical improvement and a patent AVF that was cleared for hemodialysis use. The temporal association between lead extraction and subsequent clinical improvement and clearance of the AVF for hemodialysis use is consistent with the hypothesis that the ipsilateral transvenous ICD lead may have contributed to delayed maturation through subclinical flow perturbation rather than overt mechanical stenosis. This case highlights the importance of considering ICD platform selection as a modifiable factor in dialysis access planning and illustrates the value of transitioning from transvenous to subcutaneous ICD to preserve vascular access in dialysis-dependent patients.

Cureus
Good health and well-being
Openalex Percentile: Top 6%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Delayed Arteriovenous Fistula Maturation Associated With an Ipsilateral Transvenous Implantable Cardioverter Defibrillator (ICD) Lead and Suspected Functional Hemodynamic Obstruction — VICKRAM REDDY, Vivek Reddy, et al. · Cureus (2026) | TGRS Research Map | TGRS