Active dosimeters used in interventional radiology and their response in pulsed radiation beams. Impact in clinical practice

AIM: To investigate and quantify the influence of the pulsed nature of clinical irradiation beams on the response of a specific type of active personal dosimeter (APD), and to evaluate its impact on individual occupational dose measurements of interventional radiologists and cardiologists. METHODS: APD responses were compared against passive dosimeters in a controlled experimental setting. Deviations outside the devices' specifications were addressed using a two-step correction model. A correction method based on the non-paralyzable dead-time model was developed using the instantaneous dose rate per pulse extracted from the Radiation Dose Structured Report (RDSR) at the irradiation-event level. After determining the appropriate correction factor, the method was applied to one year of clinical data comprising approximately 250,000 irradiation events. RESULTS: Among 24 occupational APDs evaluated, 14 required corrections, with the largest addition to the cumulative dose being 3.1 ± 0.1%. Five dosimeters mounted on C-arms showed that 6.61% of recorded events required correction, with a maximum correction of 5.52 ± 0.02%. Overall, the impact of pulsed radiation on recorded occupational doses was limited. CONCLUSIONS: Although the overall influence of pulsed radiation beams on APD-recorded doses was modest, verification of potential count-loss effects remains important to ensure the accuracy of cumulative dose measurements. With appropriate correction measures, APDs can be reliably used to support optimization of radiological protection for interventional specialists.

Authors

Institutions

Publication Details

Journal
Physica Medica
Published
2026-07-24
DOI
https://doi.org/10.1016/j.ejmp.2026.105886
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active dosimeters used in interventional radiology and their response in pulsed radiation beams. Impact in clinical practice

M. Ruiz, Roberto Sánchez, Antonio Gañán Mora, José Miguel Fernández Soto et al.
Physica Medica
Radiation Dose and Imaging
article

Active dosimeters used in interventional radiology and their response in pulsed radiation beams. Impact in clinical practice

M. Ruiz, Roberto Sánchez, Antonio Gañán Mora, José Miguel Fernández Soto, Adrián Mesa González, Álvaro Lens Vicente
article en

Abstract

AIM: To investigate and quantify the influence of the pulsed nature of clinical irradiation beams on the response of a specific type of active personal dosimeter (APD), and to evaluate its impact on individual occupational dose measurements of interventional radiologists and cardiologists. METHODS: APD responses were compared against passive dosimeters in a controlled experimental setting. Deviations outside the devices' specifications were addressed using a two-step correction model. A correction method based on the non-paralyzable dead-time model was developed using the instantaneous dose rate per pulse extracted from the Radiation Dose Structured Report (RDSR) at the irradiation-event level. After determining the appropriate correction factor, the method was applied to one year of clinical data comprising approximately 250,000 irradiation events. RESULTS: Among 24 occupational APDs evaluated, 14 required corrections, with the largest addition to the cumulative dose being 3.1 ± 0.1%. Five dosimeters mounted on C-arms showed that 6.61% of recorded events required correction, with a maximum correction of 5.52 ± 0.02%. Overall, the impact of pulsed radiation on recorded occupational doses was limited. CONCLUSIONS: Although the overall influence of pulsed radiation beams on APD-recorded doses was modest, verification of potential count-loss effects remains important to ensure the accuracy of cumulative dose measurements. With appropriate correction measures, APDs can be reliably used to support optimization of radiological protection for interventional specialists.

Physica MedicaVol. 148
Universidad Complutense de Madrid (ES), Catalan Institute for Water Research (ES), Hospital Clínico San Carlos (ES), Hospital Universitario Rey Juan Carlos (ES), Institut Català d'Oncologia (ES)
Consejo de Seguridad Nuclear
Good health and well-being
Openalex Percentile: Top 9%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.