Enhancing thermal performance of a heat-pipe module for air-cooled servers using self-rewetting fluids

This study experimentally investigates the performance of an air-cooled thermal module consisting of a fin stack integrated with six heat pipes charged with various self-rewetting fluids (SRWFs) for CPU cooling. Results show that thermal performance is strongly dependent on working fluid composition. Among the tested fluids, the 4 wt% 2-butanol solution delivers the most significant enhancement at high heat loads, achieving an optimal operating capacity of 500-550 W. This capacity is substantially higher than that inferred from single-pipe tests, despite the less favorable condenser boundary conditions in the air-cooled module. The improvement suggests an effective module-level enhancement, likely associated with heat sharing among multiple heat pipes and extended activation of inverse Marangoni convection. Dilute long-chain alcohol solutions (heptanol and octanol) reduce case temperature by up to 5.6°C at moderate heat loads but provide limited extension of the optimal operating capacity. Moreover, heat pipes located closest to the hotspot do not necessarily activate earlier or carry a dominant share. Instead, heat transport is uneven among different heat pipes at low heat loads. As the heat load increases, the contributions of individual heat pipe become more comparable, indicating more uniform utilization. Thermal resistance analysis reveals that the primary bottleneck resides in the condenser-to-ambient path governed by air-side convection, whereas the internal heat pipe and contact resistances are relatively minor. Nevertheless, with an optimized SRWF, the case temperature can still be maintained below 70°C at 500 W. These findings highlight the importance of jointly optimizing SRWF properties and module design for high-performance cooling.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-07-24
DOI
https://doi.org/10.1016/j.csite.2026.108377
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing thermal performance of a heat-pipe module for air-cooled servers using self-rewetting fluids

Chen-li Sun, Ya-Lin Hsiao
Case Studies in Thermal Engineering
Heat Transfer and Boiling Studies
article

Enhancing thermal performance of a heat-pipe module for air-cooled servers using self-rewetting fluids

Chen-li Sun, Ya-Lin Hsiao
article en

Abstract

This study experimentally investigates the performance of an air-cooled thermal module consisting of a fin stack integrated with six heat pipes charged with various self-rewetting fluids (SRWFs) for CPU cooling. Results show that thermal performance is strongly dependent on working fluid composition. Among the tested fluids, the 4 wt% 2-butanol solution delivers the most significant enhancement at high heat loads, achieving an optimal operating capacity of 500-550 W. This capacity is substantially higher than that inferred from single-pipe tests, despite the less favorable condenser boundary conditions in the air-cooled module. The improvement suggests an effective module-level enhancement, likely associated with heat sharing among multiple heat pipes and extended activation of inverse Marangoni convection. Dilute long-chain alcohol solutions (heptanol and octanol) reduce case temperature by up to 5.6°C at moderate heat loads but provide limited extension of the optimal operating capacity. Moreover, heat pipes located closest to the hotspot do not necessarily activate earlier or carry a dominant share. Instead, heat transport is uneven among different heat pipes at low heat loads. As the heat load increases, the contributions of individual heat pipe become more comparable, indicating more uniform utilization. Thermal resistance analysis reveals that the primary bottleneck resides in the condenser-to-ambient path governed by air-side convection, whereas the internal heat pipe and contact resistances are relatively minor. Nevertheless, with an optimized SRWF, the case temperature can still be maintained below 70°C at 500 W. These findings highlight the importance of jointly optimizing SRWF properties and module design for high-performance cooling.

Case Studies in Thermal EngineeringVol. 85
Google (United States) (US), National Taiwan University (TW)
National Science and Technology Council, Google, National Science and Technology Council
Affordable and clean energy
Openalex Percentile: Top 16%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.