Voxel-scale diffusion tensor phenomapping of the healthy and pressure-overloaded human heart

Diffusion tensor magnetic resonance imaging of the heart is typically performed at millimetre-scale resolution, yielding only four to five voxels across the ventricular wall, limiting the measurement of local spatial variation in cardiomyocyte organization. Here we present a submillimetre in vivo cardiac diffusion tensor imaging method achieved during free breathing that facilitates voxel-level characterization of myocardial microstructure. We introduce a phenomapping framework that combines voxelwise diffusion magnitude and anisotropy with radial and circumferential gradients of cardiomyocyte helix angle to identify distinct microstructural environments. The approach was developed in healthy volunteers and applied to patients with severe aortic valve stenosis, who had preserved cardiac function and marked myocardial thickening. Comparisons to conventional resolution imaging, together with downsampling analyses and ex vivo and histological validation, show that these voxel-scale features are less optimally detected using standard techniques. Four data-driven microstructural classes, defined by combined diffusion properties and orientation gradients, were observed in both healthy and pressure-overloaded hearts. Despite substantial hypertrophy, pressure overload was associated with preserved cardiomyocyte spatial organization. This framework supports studies of myocardial microstructural remodelling in vivo.

Authors

Institutions

Publication Details

Journal
Nature Biomedical Engineering
Published
2026-07-24
DOI
https://doi.org/10.1038/s41551-026-01755-y
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Voxel-scale diffusion tensor phenomapping of the healthy and pressure-overloaded human heart

Y Iris Chen, David E. Sosnovik, Christopher Nguyen, Sammy Elmariah et al.
Nature Biomedical Engineering
Advanced Neuroimaging Techniques and Applications
article

Voxel-scale diffusion tensor phenomapping of the healthy and pressure-overloaded human heart

Y Iris Chen, David E. Sosnovik, Christopher Nguyen, Sammy Elmariah, Anne Philip, Rory B. Weiner, Christopher A. Rock, Ruopeng Wang, Boris Keil, Choukri Mekkaoui
article en

Abstract

Diffusion tensor magnetic resonance imaging of the heart is typically performed at millimetre-scale resolution, yielding only four to five voxels across the ventricular wall, limiting the measurement of local spatial variation in cardiomyocyte organization. Here we present a submillimetre in vivo cardiac diffusion tensor imaging method achieved during free breathing that facilitates voxel-level characterization of myocardial microstructure. We introduce a phenomapping framework that combines voxelwise diffusion magnitude and anisotropy with radial and circumferential gradients of cardiomyocyte helix angle to identify distinct microstructural environments. The approach was developed in healthy volunteers and applied to patients with severe aortic valve stenosis, who had preserved cardiac function and marked myocardial thickening. Comparisons to conventional resolution imaging, together with downsampling analyses and ex vivo and histological validation, show that these voxel-scale features are less optimally detected using standard techniques. Four data-driven microstructural classes, defined by combined diffusion properties and orientation gradients, were observed in both healthy and pressure-overloaded hearts. Despite substantial hypertrophy, pressure overload was associated with preserved cardiomyocyte spatial organization. This framework supports studies of myocardial microstructural remodelling in vivo.

Nature Biomedical Engineering
Cleveland Clinic (US), Harvard University (US), Philipps University of Marburg (DE), University of California, San Francisco (US), Cleveland Clinic Lerner College of Medicine (US), Massachusetts General Hospital (US), Athinoula A. Martinos Center for Biomedical Imaging (US), Technische Hochschule Mittelhessen (DE), Massachusetts Institute of Technology (US)
National Heart, Lung, and Blood Institute
Openalex Percentile: Top 9%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.