Direct measurements of alveolar gas in mechanically ventilated humans

OBJECTIVE: The composition of alveolar gases is based on theoretical assumptions. The role of expired samples at the airway opening in representing the true value of mean alveolar gas remains a subject of debate. We hypothesized that phase III of oxygrams and capnograms obtained at the airway opening must be qualitative similar to the one found at the lung acini. The aim of this study is to test this hypothesis, analyzing the phase III of breath-by-breath samples of airway and alveolar gases from mechanically ventilated patients. APPROACH: The study compared expired gases at the airway opening and direct gas samples taken from peripheral lung parenchyma in ventilated patients undergoing thoracic surgery. We used video-assisted lobectomies as a model to get direct alveolar gas samples from the lobe that was removed by surgery. MAIN RESULTS: In ten anesthetized patients before lobectomy, the corresponding lung lobe was punctured by a 20G angiocath at ⁓5 mm of depth and then connected via a sampling line to sidestream and mainstream capnographs. An oscillating pattern in synchrony with the mechanical breath cycles was observed in the alveolar CO2 and O2 samples. The alveolar capnograms and oxygrams revealed an absence of phase I, very short phase II, and a similar phase III. The slope of phase III of the expired curves at the airway opening [median 2.20 (inter-quartile range 1.28) mmHg/s] were similar to the one of the alveolar mainstream capnograms [median 2.18 (inter-quartile range 1.24) mmHg/s; p = 0.76]. SIGNIFICANCE: Our findings suggest that alveolar gas can be reliably sampled at the airway opening. The similarity in the slopes of phase III between airway and alveolar samples highlights the significance of continuous gas diffusion through the alveolar-capillary membrane as well as the presence of convection- and diffusion-dependent inhomogeneities in their origin.

Authors

Institutions

Publication Details

Journal
Physiological Measurement
Published
2026-07-24
DOI
https://doi.org/10.1088/1361-6579/ae9036
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct measurements of alveolar gas in mechanically ventilated humans

Gerardo Tusman, Alejandro Carmona, Stephan Böhm, F Suarez Sipmann et al.
Physiological Measurement
Respiratory Support and Mechanisms
article

Direct measurements of alveolar gas in mechanically ventilated humans

Gerardo Tusman, Alejandro Carmona, Stephan Böhm, F Suarez Sipmann, Matías Nicolás
article en

Abstract

OBJECTIVE: The composition of alveolar gases is based on theoretical assumptions. The role of expired samples at the airway opening in representing the true value of mean alveolar gas remains a subject of debate. We hypothesized that phase III of oxygrams and capnograms obtained at the airway opening must be qualitative similar to the one found at the lung acini. The aim of this study is to test this hypothesis, analyzing the phase III of breath-by-breath samples of airway and alveolar gases from mechanically ventilated patients. APPROACH: The study compared expired gases at the airway opening and direct gas samples taken from peripheral lung parenchyma in ventilated patients undergoing thoracic surgery. We used video-assisted lobectomies as a model to get direct alveolar gas samples from the lobe that was removed by surgery. MAIN RESULTS: In ten anesthetized patients before lobectomy, the corresponding lung lobe was punctured by a 20G angiocath at ⁓5 mm of depth and then connected via a sampling line to sidestream and mainstream capnographs. An oscillating pattern in synchrony with the mechanical breath cycles was observed in the alveolar CO2 and O2 samples. The alveolar capnograms and oxygrams revealed an absence of phase I, very short phase II, and a similar phase III. The slope of phase III of the expired curves at the airway opening [median 2.20 (inter-quartile range 1.28) mmHg/s] were similar to the one of the alveolar mainstream capnograms [median 2.18 (inter-quartile range 1.24) mmHg/s; p = 0.76]. SIGNIFICANCE: Our findings suggest that alveolar gas can be reliably sampled at the airway opening. The similarity in the slopes of phase III between airway and alveolar samples highlights the significance of continuous gas diffusion through the alveolar-capillary membrane as well as the presence of convection- and diffusion-dependent inhomogeneities in their origin.

Physiological Measurement
University Medical Center (US), Hospital Privado de Comunidad (AR), Hospital Universitario de La Princesa (ES), University of Rostock (DE)
Openalex Percentile: Top 9%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.