Evaluation of dopant removal to design innovative LGADs: Measurements and simulations

The development of innovative Low-Gain Avalanche Diode architectures has required the characterisation of dopant removal at high initial concentrations. In this contribution, dopant removal is investigated using sheet resistance measurements on dedicated van der Pauw test structures. Donor removal coefficients are extracted for NPLUS implants at initial concentrations exceeding 10$^{18}$ cm$^{−3}$. The acceptor removal coefficient is also directly extracted for the PPLUS implant and validated by means of TCAD simulations, in which a SIMS-based process simulation scaled according to the extracted coefficient reproduces the measured evolution of the sheet resistance with irradiation. The results show that donor removal proceeds approximately a factor of 2–3 faster than acceptor removal, also at high initial dopant concentrations.

Authors

Publication Details

Journal
KITopen
Published
2026-07-24
DOI
https://doi.org/10.5445/ir/1000195547
Primary Topic
Silicon and Solar Cell Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of dopant removal to design innovative LGADs: Measurements and simulations

L. Massaccesi, R White, D. Passeri, L. L. Grimm et al.
KITopen
Silicon and Solar Cell Technologies
article

Evaluation of dopant removal to design innovative LGADs: Measurements and simulations

L. Massaccesi, R White, D. Passeri, L. L. Grimm, S. Galletto, V Sola, N Cartiglia, B J Regnery, A. Fondacci, A. Morozzi, M. Centis Vignali, A. R. Altamura, M. Boscardin, F. Moscatelli, M. Ferrero, T. Croci, R. Arcidiacono, G. Paternoster
article en

Abstract

The development of innovative Low-Gain Avalanche Diode architectures has required the characterisation of dopant removal at high initial concentrations. In this contribution, dopant removal is investigated using sheet resistance measurements on dedicated van der Pauw test structures. Donor removal coefficients are extracted for NPLUS implants at initial concentrations exceeding 10$^{18}$ cm$^{−3}$. The acceptor removal coefficient is also directly extracted for the PPLUS implant and validated by means of TCAD simulations, in which a SIMS-based process simulation scaled according to the extracted coefficient reproduces the measured evolution of the sheet resistance with irradiation. The results show that donor removal proceeds approximately a factor of 2–3 faster than acceptor removal, also at high initial dopant concentrations.

KITopen
Industry, innovation and infrastructure
Openalex Percentile: Top 15%
Silicon and Solar Cell Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of dopant removal to design innovative LGADs: Measurements and simulations — L. Massaccesi, R White, et al. · KITopen (2026) | TGRS Research Map | TGRS