Rooftop Bifacial Photovoltaics Under Site-Specific Roof-Albedo and Geometry Scenarios: Energy, Emission, and Economic Assessment

Rooftop bifacial photovoltaic (PV) performance depends on both the optical properties of the roof surface and the installation geometry. This simulation-based study assessed a planned rooftop PV installation on a school building in Brno, Czech Republic, using PV*SOL simulations and statistical post-processing in R. The principal dataset comprised 238 bifacial scenarios combining seven spatially distinct roof zones assigned nominal albedo values from 8% to 80%, 17 module tilts from 0∘ to 80∘, and row spacings of 1.00 and 2.10 m. Because each nominal albedo was associated with a different physical roof zone, the results represent combined roof-zone, reflectance and geometry responses rather than the isolated causal effect of albedo. The highest annual specific yield was obtained in the roof-zone scenario assigned 70% nominal albedo. The maximum was 1296.60 kWh/kWp at 1.00 m spacing and 35∘ tilt and 1359.34 kWh/kWp at 2.10 m spacing and 50∘ tilt. Under the fixed 25∘ reference configuration, the bifacial system outperformed the matched monofacial reference in all seven scenarios, with bifacial gain ranging from 7.57% to 11.23%. An empirical response-surface model reproduced the complete simulation grid with adjusted R2=0.980 and RMSE of 13.94 kWh/kWp. For the representative 6.0 kWp subarray, the maximum lifetime incremental avoided-emission difference relative to the matched 8% reference was 10.35 t CO2. Within the predefined Monte Carlo ranges, the highest-ranked scenarios produced positive incremental net present value in all 5000 sampled combinations. The findings show that roof reflectance should be evaluated together with tilt, spacing and spatial roof context. They do not establish a universally optimal albedo or rooftop configuration.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2026-07-24
DOI
https://doi.org/10.3390/su18157561
Primary Topic
Solar Radiation and Photovoltaics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rooftop Bifacial Photovoltaics Under Site-Specific Roof-Albedo and Geometry Scenarios: Energy, Emission, and Economic Assessment

Peter Tauš, Marcela Taušová, Maksym Mykhei, Dmytro Melnychenko
Sustainability
Solar Radiation and Photovoltaics
article

Rooftop Bifacial Photovoltaics Under Site-Specific Roof-Albedo and Geometry Scenarios: Energy, Emission, and Economic Assessment

Peter Tauš, Marcela Taušová, Maksym Mykhei, Dmytro Melnychenko
article en

Abstract

Rooftop bifacial photovoltaic (PV) performance depends on both the optical properties of the roof surface and the installation geometry. This simulation-based study assessed a planned rooftop PV installation on a school building in Brno, Czech Republic, using PV*SOL simulations and statistical post-processing in R. The principal dataset comprised 238 bifacial scenarios combining seven spatially distinct roof zones assigned nominal albedo values from 8% to 80%, 17 module tilts from 0∘ to 80∘, and row spacings of 1.00 and 2.10 m. Because each nominal albedo was associated with a different physical roof zone, the results represent combined roof-zone, reflectance and geometry responses rather than the isolated causal effect of albedo. The highest annual specific yield was obtained in the roof-zone scenario assigned 70% nominal albedo. The maximum was 1296.60 kWh/kWp at 1.00 m spacing and 35∘ tilt and 1359.34 kWh/kWp at 2.10 m spacing and 50∘ tilt. Under the fixed 25∘ reference configuration, the bifacial system outperformed the matched monofacial reference in all seven scenarios, with bifacial gain ranging from 7.57% to 11.23%. An empirical response-surface model reproduced the complete simulation grid with adjusted R2=0.980 and RMSE of 13.94 kWh/kWp. For the representative 6.0 kWp subarray, the maximum lifetime incremental avoided-emission difference relative to the matched 8% reference was 10.35 t CO2. Within the predefined Monte Carlo ranges, the highest-ranked scenarios produced positive incremental net present value in all 5000 sampled combinations. The findings show that roof reflectance should be evaluated together with tilt, spacing and spatial roof context. They do not establish a universally optimal albedo or rooftop configuration.

SustainabilityVol. 18(15)
Technical University of Košice (SK)
Ministerstvo školstva, vedy, výskumu a športu Slovenskej republiky
Sustainable cities and communities
Openalex Percentile: Top 6%
Solar Radiation and Photovoltaics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.