Experimental Validation of CFD Predictions for Internal Duct Airflow and Thermal Behaviour in a High-Speed Train Supply Duct Prototype: A Preliminary Stage Towards Carbody Integrated HVAC Testing

Unlike many previous high-speed train Heating, Ventilation, and Air Conditioning (HVAC) studies that combined numerical and experimental analyses within the cabin, this study evaluates the supply duct independently, offering a more targeted assessment of internal duct airflow and thermal performance. The research comprised two numerical stages and an experimental validation. The first stage evaluated four ducting geometry variations and identified the ducting system arrangement of 20 supply diffusers with a 45° air grille blocking angle as optimal for the Kereta Cepat Merah Putih (KCMP) case, keeping air velocity within the thermal comfort range for all simulated passengers. This geometry was then manufactured as a full-scale prototype and assessed in a second numerical stage against experimental measurements. The air velocity yielded a mean absolute deviation (MAD) of 0.57 m/s and a relative mean deviation (RMD) of 34.22%, while the air temperature showed an MAD of 2.13 °C and an RMD of 8.16% at duct planes, and 0.80 °C and 3.06% at duct outlets. These results demonstrate that the proposed approach of testing the supply duct independently of the cabin is able to capture the general internal duct airflow trends, even though, particularly for the temperature parameters, a large temperature discrepancy occurs at downstream locations traced to three factors: uncontrolled ambient thermal conditions in a large-scale indoor facility, simplified thermal boundary conditions in the simulation, and additional uncertainty from the non-standardised temperature measurement method. Nonetheless, it offers a promising preliminary reference for HVAC system development, prior to integrated carbody testing, although further method refinements are still required to strengthen the reliability of this approach.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2026-07-24
DOI
https://doi.org/10.3390/eng7080365
Primary Topic
Aerodynamics and Fluid Dynamics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Validation of CFD Predictions for Internal Duct Airflow and Thermal Behaviour in a High-Speed Train Supply Duct Prototype: A Preliminary Stage Towards Carbody Integrated HVAC Testing

Cahyo Wibi Yogiswara, Fauzun Fauzun, Fakhreza Areli, Samsul Ma’arip et al.
Eng—Advances in Engineering
Aerodynamics and Fluid Dynamics Research
article

Experimental Validation of CFD Predictions for Internal Duct Airflow and Thermal Behaviour in a High-Speed Train Supply Duct Prototype: A Preliminary Stage Towards Carbody Integrated HVAC Testing

Cahyo Wibi Yogiswara, Fauzun Fauzun, Fakhreza Areli, Samsul Ma’arip, Muhammad Arkan Febian Hermada, Fariz Galang Nusantara Putra Setiawan, Arsyadani Tsalisul Ilham
article en

Abstract

Unlike many previous high-speed train Heating, Ventilation, and Air Conditioning (HVAC) studies that combined numerical and experimental analyses within the cabin, this study evaluates the supply duct independently, offering a more targeted assessment of internal duct airflow and thermal performance. The research comprised two numerical stages and an experimental validation. The first stage evaluated four ducting geometry variations and identified the ducting system arrangement of 20 supply diffusers with a 45° air grille blocking angle as optimal for the Kereta Cepat Merah Putih (KCMP) case, keeping air velocity within the thermal comfort range for all simulated passengers. This geometry was then manufactured as a full-scale prototype and assessed in a second numerical stage against experimental measurements. The air velocity yielded a mean absolute deviation (MAD) of 0.57 m/s and a relative mean deviation (RMD) of 34.22%, while the air temperature showed an MAD of 2.13 °C and an RMD of 8.16% at duct planes, and 0.80 °C and 3.06% at duct outlets. These results demonstrate that the proposed approach of testing the supply duct independently of the cabin is able to capture the general internal duct airflow trends, even though, particularly for the temperature parameters, a large temperature discrepancy occurs at downstream locations traced to three factors: uncontrolled ambient thermal conditions in a large-scale indoor facility, simplified thermal boundary conditions in the simulation, and additional uncertainty from the non-standardised temperature measurement method. Nonetheless, it offers a promising preliminary reference for HVAC system development, prior to integrated carbody testing, although further method refinements are still required to strengthen the reliability of this approach.

Eng—Advances in EngineeringVol. 7(8)
Universitas Gadjah Mada (ID), Universitas Tidar (ID)
Affordable and clean energy
Openalex Percentile: Top 5%
Aerodynamics and Fluid Dynamics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.