A prospective comparative study of outcomes between zero-profile 3D-printed interbody cages and plate-augmented cages in anterior cervical discectomy and fusion

To compare the clinical and radiographic outcomes between a zero-profile 3D-printed microporous titanium alloy (3D-ZP) cage and a traditional polyetheretherketone (PEEK) cage with an anterior plate in patients undergoing single-level anterior cervical discectomy and fusion (ACDF) for cervical spondylotic myelopathy (CSM). A prospective, open-label randomized controlled trial was conducted from January 2022 to January 2024. Patients diagnosed with single-level CSM were randomized to receive either a 3D-ZP cage or a PEEK cage with an anterior plate. The primary outcome was prosthesis subsidence rate. Secondary outcomes included operative time, incidence of dysphagia, visual analog scale (VAS) for neck pain, Japanese Orthopedic Association (JOA) score, Neck Disability Index (NDI), segmental Cobb angle, and fusion status. Follow-ups were conducted at 1 week, 3, 12, and 24 months postoperatively. A total of 113 patients completed the 24-month follow-up (3D-ZP group: n = 52, PEEK group: n = 61). The 3D-ZP group demonstrated a significantly lower prosthesis subsidence rate compared to the PEEK group (9.6% vs. 27.9%; RR = 0.35, 95% CI 0.14–0.87, P = 0.015). Operative time was shorter in the 3D-ZP group (65.63 ± 11.42 vs. 78.64 ± 14.81 min; MD=–13.00, 95% CI − 18.00 to − 8.01, P < 0.001). The incidence of dysphagia was also lower in the 3D-ZP group at both 1-week (13.5% vs. 45.9%, RR = 0.29, 95% CI 0.14–0.62, P < 0.001) and 24-month follow-ups (1.9% vs. 21.3%; RR = 0.09, 95% CI 0.01–0.67, P = 0.002). No significant differences were observed in JOA improvement rate or fusion rate between the two groups. Radiographically, the 3D-ZP group maintained significantly greater disc space height and segmental lordosis at 24 months. In single-level ACDF for CSM, the zero-profile 3D-printed titanium cage offers advantages over the traditional PEEK-and-plate construct, including shorter operative time, reduced incidence of dysphagia, and lower prosthesis subsidence rate, while achieving comparable neurological recovery and fusion outcomes.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-07-24
DOI
https://doi.org/10.1038/s41598-026-63918-w
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A prospective comparative study of outcomes between zero-profile 3D-printed interbody cages and plate-augmented cages in anterior cervical discectomy and fusion

Yan He, Yuwei Li, Bowen Li, Xiuzhi Li et al.
Scientific Reports
Cervical and Thoracic Myelopathy
article

A prospective comparative study of outcomes between zero-profile 3D-printed interbody cages and plate-augmented cages in anterior cervical discectomy and fusion

Yan He, Yuwei Li, Bowen Li, Xiuzhi Li, Wei Cui, Haijiao Wang
article en

Abstract

To compare the clinical and radiographic outcomes between a zero-profile 3D-printed microporous titanium alloy (3D-ZP) cage and a traditional polyetheretherketone (PEEK) cage with an anterior plate in patients undergoing single-level anterior cervical discectomy and fusion (ACDF) for cervical spondylotic myelopathy (CSM). A prospective, open-label randomized controlled trial was conducted from January 2022 to January 2024. Patients diagnosed with single-level CSM were randomized to receive either a 3D-ZP cage or a PEEK cage with an anterior plate. The primary outcome was prosthesis subsidence rate. Secondary outcomes included operative time, incidence of dysphagia, visual analog scale (VAS) for neck pain, Japanese Orthopedic Association (JOA) score, Neck Disability Index (NDI), segmental Cobb angle, and fusion status. Follow-ups were conducted at 1 week, 3, 12, and 24 months postoperatively. A total of 113 patients completed the 24-month follow-up (3D-ZP group: n = 52, PEEK group: n = 61). The 3D-ZP group demonstrated a significantly lower prosthesis subsidence rate compared to the PEEK group (9.6% vs. 27.9%; RR = 0.35, 95% CI 0.14–0.87, P = 0.015). Operative time was shorter in the 3D-ZP group (65.63 ± 11.42 vs. 78.64 ± 14.81 min; MD=–13.00, 95% CI − 18.00 to − 8.01, P < 0.001). The incidence of dysphagia was also lower in the 3D-ZP group at both 1-week (13.5% vs. 45.9%, RR = 0.29, 95% CI 0.14–0.62, P < 0.001) and 24-month follow-ups (1.9% vs. 21.3%; RR = 0.09, 95% CI 0.01–0.67, P = 0.002). No significant differences were observed in JOA improvement rate or fusion rate between the two groups. Radiographically, the 3D-ZP group maintained significantly greater disc space height and segmental lordosis at 24 months. In single-level ACDF for CSM, the zero-profile 3D-printed titanium cage offers advantages over the traditional PEEK-and-plate construct, including shorter operative time, reduced incidence of dysphagia, and lower prosthesis subsidence rate, while achieving comparable neurological recovery and fusion outcomes.

Scientific Reports
Ministry of Education of the People's Republic of China (CN), Peking University (CN), Henan Institute of Technology (CN), Luohe Medical College (CN), Peking University Third Hospital (CN)
Good health and well-being
Openalex Percentile: Top 7%
Cervical and Thoracic Myelopathy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.