In vivo study of the effect of composition and implantation site on scaffold degradation rate

Tissue engineering devices stabilize wounds, then degrade. However, published degradation rates often conflict. Incorporating monitoring functionality into devices allows real-time assessment of degradation and failure, but requires contrast agents, as polymer devices are invisible to most medical imaging modalities. Therefore, computed tomography (CT)-visible composite scaffolds were created from 5-20 wt% tantalum oxide (TaOx) nanoparticles in polymers with distinct degradation profiles: polycaprolactone, poly(lactide-co-glycolide) (PLGA) 85:15 and PLGA 50:50, representing slow, medium and fast degrading materials. Scaffolds, mimicking biomedical devices, were implanted into mice intramuscularly or intraperitoneally, and monitored via CT over 20 weeks. Scaffold degradation profile was dictated by polymer matrix, regardless of nanoparticle addition. Foreign body response was dependent on implant site and in mid-degrading composites degradation rates transitioned from linear degradation intramuscularly to exponential degradation intraperitoneally. Nanoparticle excretion via liver and spleen lagged polymer degradation. Overall, real time tracking of device behavior was demonstrated, advancing an era of personalized medicine. Tissue engineering devices degrade over time, but monitoring their degradation requires imaging contrast agents. Here, the authors developed computed tomography-visible TaOx-polymer composite scaffolds that enabled real-time in vivo tracking, showing that degradation depended on the polymer matrix and implantation site, supporting personalized medicine.

Authors

Institutions

Publication Details

Journal
Communications Materials
Published
2026-07-24
DOI
https://doi.org/10.1038/s43246-026-01308-5
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vivo study of the effect of composition and implantation site on scaffold degradation rate

Matti Kiupel, Erik M. Shapiro, Kendell M. Pawelec, Jeremy M.L. Hix et al.
Communications Materials
Bone Tissue Engineering Materials
article

In vivo study of the effect of composition and implantation site on scaffold degradation rate

Matti Kiupel, Erik M. Shapiro, Kendell M. Pawelec, Jeremy M.L. Hix, Niharika Sinha, Keith W. MacRenaris, Arianna Troia, Thomas V. O’Halloran
article en

Abstract

Tissue engineering devices stabilize wounds, then degrade. However, published degradation rates often conflict. Incorporating monitoring functionality into devices allows real-time assessment of degradation and failure, but requires contrast agents, as polymer devices are invisible to most medical imaging modalities. Therefore, computed tomography (CT)-visible composite scaffolds were created from 5-20 wt% tantalum oxide (TaOx) nanoparticles in polymers with distinct degradation profiles: polycaprolactone, poly(lactide-co-glycolide) (PLGA) 85:15 and PLGA 50:50, representing slow, medium and fast degrading materials. Scaffolds, mimicking biomedical devices, were implanted into mice intramuscularly or intraperitoneally, and monitored via CT over 20 weeks. Scaffold degradation profile was dictated by polymer matrix, regardless of nanoparticle addition. Foreign body response was dependent on implant site and in mid-degrading composites degradation rates transitioned from linear degradation intramuscularly to exponential degradation intraperitoneally. Nanoparticle excretion via liver and spleen lagged polymer degradation. Overall, real time tracking of device behavior was demonstrated, advancing an era of personalized medicine. Tissue engineering devices degrade over time, but monitoring their degradation requires imaging contrast agents. Here, the authors developed computed tomography-visible TaOx-polymer composite scaffolds that enabled real-time in vivo tracking, showing that degradation depended on the polymer matrix and implantation site, supporting personalized medicine.

Communications Materials
Michigan State University (US)
Michigan State University, National Institutes of Health, College of Engineering, Michigan State University, NIH Office of the Director, National Institute of General Medical Sciences, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 16%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.