Off-Hours Robotic-Assisted Spine Instrumentation in a Teaching Hospital: Feasibility Under Increased Emergency and Workflow Burden

Background/Objectives: Robotic-assisted spine instrumentation is resource-intensive and may be challenging during off-hours emergency care. This study evaluated its operational feasibility and technical reliability in a teaching hospital. Methods: We performed an exploratory post hoc secondary analysis of 146 consecutive robotic-assisted spine instrumentation procedures comprising 1006 pedicle or sacral–alar–iliac screws. Off-hours surgery was defined as night and/or weekend surgery. The primary outcome was screw-level Gertzbein–Robbins (GR) accuracy. Secondary outcomes included workflow, perioperative, and 30-day clinical measures. Because all off-hours procedures were emergencies, an additional sensitivity analysis compared off-hours with regular-hours emergency procedures. Results: Sixteen procedures comprising 150 screws were performed off-hours. In the unadjusted primary comparison, off-hours cases had greater trauma and emergency burden, more frequent repeat imaging or re-registration, higher intensive care unit (ICU) utilization, and longer hospitalization. GR A/B accuracy was 96.0% off-hours and 98.2% during regular hours, while GR C–E rates were 4.0% and 1.8%, respectively. Severe deviations were uncommon, and no screw-related postoperative neurological deficit occurred. In the emergency-only analysis, GR A/B accuracy was 96.0% off-hours and 96.7% during regular-hours emergency surgery, while several perioperative differences were attenuated. Conclusions: Robotic-assisted spine instrumentation remained operationally feasible during off-hours emergency surgery, with high screw accuracy and few severe deviations. However, the small and highly selected off-hours subgroup and marked case-mix differences preclude conclusions regarding equivalence, comparative safety, or an independent effect of surgical timing. These findings should be considered hypothesis-generating.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-07-24
DOI
https://doi.org/10.3390/jcm15155803
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Off-Hours Robotic-Assisted Spine Instrumentation in a Teaching Hospital: Feasibility Under Increased Emergency and Workflow Burden

Jaqueline Lattmann, Kristina Catalano, Lukas Andereggen, Gerrit Alexander Schubert et al.
Journal of Clinical Medicine
Spinal Fractures and Fixation Techniques
article

Off-Hours Robotic-Assisted Spine Instrumentation in a Teaching Hospital: Feasibility Under Increased Emergency and Workflow Burden

Jaqueline Lattmann, Kristina Catalano, Lukas Andereggen, Gerrit Alexander Schubert, Julien Jost, Thomas Rhomberg, Markus Bruder, Debora Cipriani
article en

Abstract

Background/Objectives: Robotic-assisted spine instrumentation is resource-intensive and may be challenging during off-hours emergency care. This study evaluated its operational feasibility and technical reliability in a teaching hospital. Methods: We performed an exploratory post hoc secondary analysis of 146 consecutive robotic-assisted spine instrumentation procedures comprising 1006 pedicle or sacral–alar–iliac screws. Off-hours surgery was defined as night and/or weekend surgery. The primary outcome was screw-level Gertzbein–Robbins (GR) accuracy. Secondary outcomes included workflow, perioperative, and 30-day clinical measures. Because all off-hours procedures were emergencies, an additional sensitivity analysis compared off-hours with regular-hours emergency procedures. Results: Sixteen procedures comprising 150 screws were performed off-hours. In the unadjusted primary comparison, off-hours cases had greater trauma and emergency burden, more frequent repeat imaging or re-registration, higher intensive care unit (ICU) utilization, and longer hospitalization. GR A/B accuracy was 96.0% off-hours and 98.2% during regular hours, while GR C–E rates were 4.0% and 1.8%, respectively. Severe deviations were uncommon, and no screw-related postoperative neurological deficit occurred. In the emergency-only analysis, GR A/B accuracy was 96.0% off-hours and 96.7% during regular-hours emergency surgery, while several perioperative differences were attenuated. Conclusions: Robotic-assisted spine instrumentation remained operationally feasible during off-hours emergency surgery, with high screw accuracy and few severe deviations. However, the small and highly selected off-hours subgroup and marked case-mix differences preclude conclusions regarding equivalence, comparative safety, or an independent effect of surgical timing. These findings should be considered hypothesis-generating.

Journal of Clinical MedicineVol. 15(15)
Goethe University Frankfurt (DE), University of Bern (CH), University Hospital Frankfurt (DE), Kantonsspital Aarau (CH), RWTH Aachen University (DE)
Openalex Percentile: Top 7%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.