Automatic detection of frontal ECG lead interchange using inter-lead correlation analysis in a 12-lead vital signs monitoring system

Electrode misplacement and interchange remain significant sources of error during electrocardiogram (ECG) acquisition, particularly in portable and connected systems operating within the Internet of Medical Things (IoMT). Such errors can substantially modify ECG morphology, disrupt inter-lead relationships, and mimic pathological cardiac conditions, thereby compromising diagnostic reliability. While commercial devices incorporate proprietary mechanisms for detecting lead reversal, their closed architectures limit transparency and adaptability for research and educational purposes. This study presents an intelligent system for real-time detection of ECG electrode interchange based on inter-lead correlation analysis in standard 12-lead recordings, with limb and augmented leads computed according to conventional clinical definitions. The proposed approach focuses on frontal-plane lead interchange scenarios and exploits short temporal windows to characterize stable correlation patterns associated with specific electrode configurations. The methodology was evaluated using eleven clinically relevant cases involving the frontal leads (I, II, III, aVR, aVL, and aVF). The results demonstrate that inter-lead correlation patterns provide a robust and interpretable means of identifying electrode interchange, allowing technical acquisition errors to be distinguished from physiological signal variations. Beyond supporting acquisition-stage quality control, the proposed framework offers a practical foundation for training applications and provides a scalable basis for future extension toward precordial lead misplacement detection, which is not addressed in the present study.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2026-07-24
DOI
https://doi.org/10.1016/j.bspc.2026.111110
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic detection of frontal ECG lead interchange using inter-lead correlation analysis in a 12-lead vital signs monitoring system

Paola A. Niño Suárez, Hiram A. Hernández Rivera, Jorge A. Soto Cajiga, Cristian H. Sánchez Saquín et al.
Biomedical Signal Processing and Control
ECG Monitoring and Analysis
article

Automatic detection of frontal ECG lead interchange using inter-lead correlation analysis in a 12-lead vital signs monitoring system

Paola A. Niño Suárez, Hiram A. Hernández Rivera, Jorge A. Soto Cajiga, Cristian H. Sánchez Saquín, Francisco D. Pérez Reynoso
article en

Abstract

Electrode misplacement and interchange remain significant sources of error during electrocardiogram (ECG) acquisition, particularly in portable and connected systems operating within the Internet of Medical Things (IoMT). Such errors can substantially modify ECG morphology, disrupt inter-lead relationships, and mimic pathological cardiac conditions, thereby compromising diagnostic reliability. While commercial devices incorporate proprietary mechanisms for detecting lead reversal, their closed architectures limit transparency and adaptability for research and educational purposes. This study presents an intelligent system for real-time detection of ECG electrode interchange based on inter-lead correlation analysis in standard 12-lead recordings, with limb and augmented leads computed according to conventional clinical definitions. The proposed approach focuses on frontal-plane lead interchange scenarios and exploits short temporal windows to characterize stable correlation patterns associated with specific electrode configurations. The methodology was evaluated using eleven clinically relevant cases involving the frontal leads (I, II, III, aVR, aVL, and aVF). The results demonstrate that inter-lead correlation patterns provide a robust and interpretable means of identifying electrode interchange, allowing technical acquisition errors to be distinguished from physiological signal variations. Beyond supporting acquisition-stage quality control, the proposed framework offers a practical foundation for training applications and provides a scalable basis for future extension toward precordial lead misplacement detection, which is not addressed in the present study.

Biomedical Signal Processing and ControlVol. 127
Center for Engineering and Industrial Development (MX), Instituto Politécnico Nacional (MX)
Centro de Ingeniería y Desarrollo Industrial
Quality Education
Openalex Percentile: Top 9%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.