Wearable exoskeleton upper limb device based on soft actuators: design, characterization, and preliminary testing

This article presents the development of a wearable exoskeleton robotic device designed for the motor recovery of the upper limbs following stroke, in which the possibility of integrating soft actuators was explored. The device is designed for multi-joint assistance, with the ability to help patients in recovery training with sequential movements of the elbow, wrist, and fingers in flexion/extension and adduction/abduction. Based on the specific characteristics of each target area, the device integrates three different types of soft actuators, whose force and range of motion characteristics were analysed using numerical and experimental methods. The relatively low force/torque characteristics in the targeted areas of the limb have made it possible to develop a compact, lightweight system that offers comfort during long periods of use. The device is made entirely of soft materials and textiles, and the soft actuators have been designed based on average anthropometric characteristics. The force development and their range of motion were the defining characteristics analysed of the three different types of soft actuators (bellows-type textile actuator, McKibben-type artificial muscles, and PneuNets multisegment actuators -MSA). The device integrates a closed-loop control, increasing performance as well as patients' adaptability. According to the results, the actuators develop sufficient force for recovery training, and preliminary analysis regarding range of motion shows an error of 2.29 % for finger flexion, 4 % and 10.5 % for adduction/abduction, for forearm flexion: 4.4 %, and higher for hand flexion/extension. In accordance with these results, future directions concentrate on investigating the device on stroke patients and augmenting the portability of the mechanism.

Authors

Institutions

Publication Details

Journal
Bioinspiration & Biomimetics
Published
2026-07-24
DOI
https://doi.org/10.1088/1748-3190/ae8fc2
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable exoskeleton upper limb device based on soft actuators: design, characterization, and preliminary testing

Cristina–Maria Biriș, D Rusu, Mihai Crenganiș, Claudia–Emilia Gîrjob et al.
Bioinspiration & Biomimetics
Stroke Rehabilitation and Recovery
article

Wearable exoskeleton upper limb device based on soft actuators: design, characterization, and preliminary testing

Cristina–Maria Biriș, D Rusu, Mihai Crenganiș, Claudia–Emilia Gîrjob, Dan Mandru, Sever Gabriel Racz
article en

Abstract

This article presents the development of a wearable exoskeleton robotic device designed for the motor recovery of the upper limbs following stroke, in which the possibility of integrating soft actuators was explored. The device is designed for multi-joint assistance, with the ability to help patients in recovery training with sequential movements of the elbow, wrist, and fingers in flexion/extension and adduction/abduction. Based on the specific characteristics of each target area, the device integrates three different types of soft actuators, whose force and range of motion characteristics were analysed using numerical and experimental methods. The relatively low force/torque characteristics in the targeted areas of the limb have made it possible to develop a compact, lightweight system that offers comfort during long periods of use. The device is made entirely of soft materials and textiles, and the soft actuators have been designed based on average anthropometric characteristics. The force development and their range of motion were the defining characteristics analysed of the three different types of soft actuators (bellows-type textile actuator, McKibben-type artificial muscles, and PneuNets multisegment actuators -MSA). The device integrates a closed-loop control, increasing performance as well as patients' adaptability. According to the results, the actuators develop sufficient force for recovery training, and preliminary analysis regarding range of motion shows an error of 2.29 % for finger flexion, 4 % and 10.5 % for adduction/abduction, for forearm flexion: 4.4 %, and higher for hand flexion/extension. In accordance with these results, future directions concentrate on investigating the device on stroke patients and augmenting the portability of the mechanism.

Bioinspiration & Biomimetics
Lucian Blaga University of Sibiu (RO), Technical University of Cluj-Napoca (RO)
Openalex Percentile: Top 12%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.