Association between video laryngoscope blade geometry and first-pass success during prehospital intubation: a prospective bicentric observational study

Abstract Background Endotracheal intubation (ETI) is a cornerstone of advanced prehospital airway management but remains associated with considerable procedural risk, particularly when multiple intubation attempts are required. First-pass success (FPS) is an established quality indicator because repeated attempts increase the risk of hypoxaemia, aspiration, oesophageal intubation, haemodynamic instability and cardiac arrest [1–4]. Although video laryngoscopy (VL) is recommended by international airway guidelines [5–8], evidence regarding the optimal blade geometry for prehospital airway management remains limited. We investigated the association between video laryngoscope blade geometry and FPS in a physician-staffed helicopter emergency medical service (HEMS). Methods We conducted a prospective bicentric observational study at two German physician-staffed HEMS bases between January 2017 and December 2019. Consecutive prehospital ETIs performed using the C-MAC ® PM video laryngoscope were prospectively documented. Blade selection was at the discretion of the treating physician. The primary outcome was FPS. Secondary outcomes included glottic visualisation, intubation duration, number of attempts, airway-related adverse events and video laryngoscopy-associated technical problems. Results A total of 283 video laryngoscopic intubations were analysed. Overall first-pass success (FPS) was 71.0% (201/283). Blade-specific FPS rates were 72.0% for Macintosh size 3, 72.6% for Macintosh size 4 and 61.9% for the hyper angulated D-Blade, without significant differences between blade geometries ( p = 0.601). Adequate glottic visualisation (Cormack–Lehane grade I–II) was achieved in 96.8% of patients. Mean intubation duration was 42.5 ± 34.2 s. Airway-related adverse events occurred in 5.7% of patients and video laryngoscopy-associated technical problems in 12.6%. In an exploratory multivariable analysis, blade geometry was not independently associated with FPS, whereas difficult laryngoscopy conditions, poor glottic visualisation and technical problems were associated with failed first-pass intubation. Conclusions Video laryngoscopy provided excellent glottic visualisation irrespective of blade geometry. Neither univariable nor exploratory multivariable analyses demonstrated an independent association between blade geometry and first-pass success. Instead, difficult airway conditions, poor glottic visualisation and video laryngoscopy-associated technical problems appeared to exert a greater influence on procedural success. Given the observational design and limited number of hyper angulated blade intubations, these findings should be regarded as hypothesis-generating and require confirmation in larger prospective multicentre studies incorporating standardised difficult-airway assessment.

Authors

Institutions

Publication Details

Journal
BMC Emergency Medicine
Published
2026-07-23
DOI
https://doi.org/10.1186/s12873-026-01701-w
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Association between video laryngoscope blade geometry and first-pass success during prehospital intubation: a prospective bicentric observational study

Andreas García Bardon, Willi Schmidbauer, Martin Schiffarth, Andreas Schwartz et al.
BMC Emergency Medicine
Airway Management and Intubation Techniques
article

Association between video laryngoscope blade geometry and first-pass success during prehospital intubation: a prospective bicentric observational study

Andreas García Bardon, Willi Schmidbauer, Martin Schiffarth, Andreas Schwartz, Tobias Grübl, Marc Royko, Christoph Jänig, Benedikt Harmuth, Maja Iversen, Tim Piepho, Daniel Schroeder, Holger Meyer
article en

Abstract

Abstract Background Endotracheal intubation (ETI) is a cornerstone of advanced prehospital airway management but remains associated with considerable procedural risk, particularly when multiple intubation attempts are required. First-pass success (FPS) is an established quality indicator because repeated attempts increase the risk of hypoxaemia, aspiration, oesophageal intubation, haemodynamic instability and cardiac arrest [1–4]. Although video laryngoscopy (VL) is recommended by international airway guidelines [5–8], evidence regarding the optimal blade geometry for prehospital airway management remains limited. We investigated the association between video laryngoscope blade geometry and FPS in a physician-staffed helicopter emergency medical service (HEMS). Methods We conducted a prospective bicentric observational study at two German physician-staffed HEMS bases between January 2017 and December 2019. Consecutive prehospital ETIs performed using the C-MAC ® PM video laryngoscope were prospectively documented. Blade selection was at the discretion of the treating physician. The primary outcome was FPS. Secondary outcomes included glottic visualisation, intubation duration, number of attempts, airway-related adverse events and video laryngoscopy-associated technical problems. Results A total of 283 video laryngoscopic intubations were analysed. Overall first-pass success (FPS) was 71.0% (201/283). Blade-specific FPS rates were 72.0% for Macintosh size 3, 72.6% for Macintosh size 4 and 61.9% for the hyper angulated D-Blade, without significant differences between blade geometries ( p = 0.601). Adequate glottic visualisation (Cormack–Lehane grade I–II) was achieved in 96.8% of patients. Mean intubation duration was 42.5 ± 34.2 s. Airway-related adverse events occurred in 5.7% of patients and video laryngoscopy-associated technical problems in 12.6%. In an exploratory multivariable analysis, blade geometry was not independently associated with FPS, whereas difficult laryngoscopy conditions, poor glottic visualisation and technical problems were associated with failed first-pass intubation. Conclusions Video laryngoscopy provided excellent glottic visualisation irrespective of blade geometry. Neither univariable nor exploratory multivariable analyses demonstrated an independent association between blade geometry and first-pass success. Instead, difficult airway conditions, poor glottic visualisation and video laryngoscopy-associated technical problems appeared to exert a greater influence on procedural success. Given the observational design and limited number of hyper angulated blade intubations, these findings should be regarded as hypothesis-generating and require confirmation in larger prospective multicentre studies incorporating standardised difficult-airway assessment.

BMC Emergency MedicineVol. 26(1)
Trier University of Applied Sciences (DE), Bundeswehrkrankenhaus (DE), Airbus (Germany) (DE), Bundeswehrzentralkrankenhaus Koblenz (DE), Universität Trier (DE)
No poverty
Openalex Percentile: Top 7%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.