Plate-type steel fuse for enhancing the seismic performance of steel storage rack structures

Past earthquakes have shown that steel storage rack structures are significantly vulnerable due to their specific structural characteristics, which is primarily governed by hook-type beam-to-upright joints. As adding devices or structural elements can obstruct storage bays and limit access, seismic retrofit of these structures is challenging. This study proposes a damping device which consists of a steel plate with two fuse notches and can be attached to beam-to-upright connections without affecting the structure's functionality. In addition to enhancing structural integrity and stiffness, this plate-type fuse dissipates seismic energy through controlled in-plane yielding when subjected to joint rotations. The mechanical behavior of the fuse is theoretically derived and verified using finite element analyses. To this end, an experimental rack subassembly test under cyclic loads is modeled and validated in both Ansys and OpenSees. Subsequently, it is retrofitted with the proposed fuse and its hysteretic behavior and the accuracy of the derived theoretical formulations are evaluated in a comprehensive parametric study. To further investigate the effectiveness of the developed damping device, a benchmark three-story four-bay rack structure is modeled and retrofitted in OpenSees. The seismic performance of this structure is evaluated and compared before and after retrofit using nonlinear time history analysis under a suite of ground motion records and pushover analysis. The results show that the original structure experiences global failure and dynamic instability under the Maximum Considered Earthquake hazard level, whereas the retrofitted structure meets the Collapse Prevention performance objective as designed using the established theoretical formulations.

Authors

Institutions

Publication Details

Journal
Soil Dynamics and Earthquake Engineering
Published
2026-07-23
DOI
https://doi.org/10.1016/j.soildyn.2026.110553
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Plate-type steel fuse for enhancing the seismic performance of steel storage rack structures

Jinkoo Kim, Mohammad Mahdi Javidan, Seunghee Park, Sajid Hussain
Soil Dynamics and Earthquake Engineering
Seismic Performance and Analysis
article

Plate-type steel fuse for enhancing the seismic performance of steel storage rack structures

Jinkoo Kim, Mohammad Mahdi Javidan, Seunghee Park, Sajid Hussain
article en

Abstract

Past earthquakes have shown that steel storage rack structures are significantly vulnerable due to their specific structural characteristics, which is primarily governed by hook-type beam-to-upright joints. As adding devices or structural elements can obstruct storage bays and limit access, seismic retrofit of these structures is challenging. This study proposes a damping device which consists of a steel plate with two fuse notches and can be attached to beam-to-upright connections without affecting the structure's functionality. In addition to enhancing structural integrity and stiffness, this plate-type fuse dissipates seismic energy through controlled in-plane yielding when subjected to joint rotations. The mechanical behavior of the fuse is theoretically derived and verified using finite element analyses. To this end, an experimental rack subassembly test under cyclic loads is modeled and validated in both Ansys and OpenSees. Subsequently, it is retrofitted with the proposed fuse and its hysteretic behavior and the accuracy of the derived theoretical formulations are evaluated in a comprehensive parametric study. To further investigate the effectiveness of the developed damping device, a benchmark three-story four-bay rack structure is modeled and retrofitted in OpenSees. The seismic performance of this structure is evaluated and compared before and after retrofit using nonlinear time history analysis under a suite of ground motion records and pushover analysis. The results show that the original structure experiences global failure and dynamic instability under the Maximum Considered Earthquake hazard level, whereas the retrofitted structure meets the Collapse Prevention performance objective as designed using the established theoretical formulations.

Soil Dynamics and Earthquake EngineeringVol. 210
Sungkyunkwan University (KR)
Ministry of Science and ICT, South Korea
Sustainable cities and communities
Openalex Percentile: Top 13%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.