The Effect of Irradiation Setup Conditions on Cell Viability in Tumor Cell Cultures: An Investigation on Multi-well Plates

Air gaps in multi-well cell culture plates can disrupt electronic equilibrium and introduce uncertainties in delivered dose during in vitro irradiation experiments. This study evaluated the impact of different bottom-up irradiation setups on short-term cell viability using an RW3 solid water phantom system. MCF-7 cells were irradiated with 6-MV photons (200-cGy) under four experimental configurations. One-way ANOVA demonstrated no statistically significant differences among setups [F(3,8)=0.503, p=0.691]. Tukey HSD post-hoc analysis confirmed the absence of significant pairwise differences (p>0.05). A subsequent power analysis (η2=0.159; Cohen's f=0.434) revealed an observed power of 0.15. These findings indicate that additional bolus or RW3 configurations do not significantly affect short-term cell viability when bottom-up geometry and appropriate buildup conditions are maintained.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2026-07-23
DOI
https://doi.org/10.1097/hp.0000000000002181
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Irradiation Setup Conditions on Cell Viability in Tumor Cell Cultures: An Investigation on Multi-well Plates

Binnaz Sarper, Gülşah Özkan, Ayşegül Ünal Karabey, Yusufhan Yazır et al.
Health Physics
Advanced Radiotherapy Techniques
article

The Effect of Irradiation Setup Conditions on Cell Viability in Tumor Cell Cultures: An Investigation on Multi-well Plates

Binnaz Sarper, Gülşah Özkan, Ayşegül Ünal Karabey, Yusufhan Yazır, Berna Tırpancı, Umut Diremsizoğlu, Canan Öztürk
article en

Abstract

Air gaps in multi-well cell culture plates can disrupt electronic equilibrium and introduce uncertainties in delivered dose during in vitro irradiation experiments. This study evaluated the impact of different bottom-up irradiation setups on short-term cell viability using an RW3 solid water phantom system. MCF-7 cells were irradiated with 6-MV photons (200-cGy) under four experimental configurations. One-way ANOVA demonstrated no statistically significant differences among setups [F(3,8)=0.503, p=0.691]. Tukey HSD post-hoc analysis confirmed the absence of significant pairwise differences (p>0.05). A subsequent power analysis (η2=0.159; Cohen's f=0.434) revealed an observed power of 0.15. These findings indicate that additional bolus or RW3 configurations do not significantly affect short-term cell viability when bottom-up geometry and appropriate buildup conditions are maintained.

Health Physics
Kocaeli Üniversitesi (TR)
Clean water and sanitation
Openalex Percentile: Top 9%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.