Aptamer/Nanozyme Chemical Sensors for On-Site Glyphosate Determination in Agricultural Runoff: Classification, Operating Principles, and Analytical Applicability

This critical perspective review first classifies glyphosate-sensing platforms and then evaluates their analytical applicability to agricultural runoff. Platforms are divided at the primary level into optical and electrochemical transduction, because these families measure different physical signals and have different sources of matrix interference. They are then grouped by the process that produces selectivity or signal change: direct interaction or metal coordination, affinity recognition by aptamers, antibodies, or molecularly imprinted polymers, catalytic modulation by enzymes or nanozymes, and separation or preconcentration before detection. This hierarchy distinguishes recognition chemistry from transduction method and device configuration. The review next defines four intended analytical applications—trace surveillance, runoff event screening, spill triage, and laboratory-adjacent confirmation—and compares them in terms of matrix, target concentration range, sample preparation, reporting metrics, and quality control requirements. Glyphosate occurs in dissolved and particle-associated forms, degrades mainly to AMPA, and coexists with phosphate, glufosinate, divalent cations, natural organic matter, and suspended sediment. Consequently, the lowest reported LOD is rarely the sole criterion for selecting a method. Matrix-matched calibration, spike recovery, selectivity, response time, storage stability, reader requirements, and invalid result rules determine whether an assay is suitable for a specified analytical application. The most defensible near-term approach combines matrix-specific sample preparation, platform-specific controls, and LC-MS/MS confirmation when results are regulatory, contested, or close to a decision threshold.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2026-07-23
DOI
https://doi.org/10.3390/chemosensors14080170
Primary Topic
Freshwater macroinvertebrate diversity and ecology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aptamer/Nanozyme Chemical Sensors for On-Site Glyphosate Determination in Agricultural Runoff: Classification, Operating Principles, and Analytical Applicability

Li Fu, Meiqing Jin, Qingwei Zhou
Chemosensors
Freshwater macroinvertebrate diversity and ecology
article

Aptamer/Nanozyme Chemical Sensors for On-Site Glyphosate Determination in Agricultural Runoff: Classification, Operating Principles, and Analytical Applicability

Li Fu, Meiqing Jin, Qingwei Zhou
article en

Abstract

This critical perspective review first classifies glyphosate-sensing platforms and then evaluates their analytical applicability to agricultural runoff. Platforms are divided at the primary level into optical and electrochemical transduction, because these families measure different physical signals and have different sources of matrix interference. They are then grouped by the process that produces selectivity or signal change: direct interaction or metal coordination, affinity recognition by aptamers, antibodies, or molecularly imprinted polymers, catalytic modulation by enzymes or nanozymes, and separation or preconcentration before detection. This hierarchy distinguishes recognition chemistry from transduction method and device configuration. The review next defines four intended analytical applications—trace surveillance, runoff event screening, spill triage, and laboratory-adjacent confirmation—and compares them in terms of matrix, target concentration range, sample preparation, reporting metrics, and quality control requirements. Glyphosate occurs in dissolved and particle-associated forms, degrades mainly to AMPA, and coexists with phosphate, glufosinate, divalent cations, natural organic matter, and suspended sediment. Consequently, the lowest reported LOD is rarely the sole criterion for selecting a method. Matrix-matched calibration, spike recovery, selectivity, response time, storage stability, reader requirements, and invalid result rules determine whether an assay is suitable for a specified analytical application. The most defensible near-term approach combines matrix-specific sample preparation, platform-specific controls, and LC-MS/MS confirmation when results are regulatory, contested, or close to a decision threshold.

ChemosensorsVol. 14(8)
Hangzhou Dianzi University (CN)
Zero hunger
Openalex Percentile: Top 9%
Freshwater macroinvertebrate diversity and ecology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.