Cells perceive the distribution differences of adhesion ligands and consequently establish cellular polarization to regulate osteogenic differentiation

Engineering implant topography has emerged as a promising strategy to promote bone regeneration in complex fractures and large bone defects. Among such topographies, TiO 2 nanotubes serve as a model topography and have been shown, within a certain range, to positively regulate osteogenic differentiation through diameter-dependent effects. However, the underlying mechanisms remains fragmentary. Here, we revealed how cells perceived nanotube interfaces and identified the intracellular force-based mechanotransduction that arose from interface perception. We unexpectedly found that cellular perception of nanotube interfaces depended on diameter-associated topographical cues that induced differential distribution of adhesive ligands. Cells engaged these adhesive ligands to modulate focal adhesion (FA) organization, with small and many FAs forming on the small-diameter nanotubes (30 nm), whereas fewer but larger FAs formed on the large-diameter nanotubes (100 nm). Fewer but larger FAs regulated cytoskeletal assembly, generating greater intracellular force and enhancing cellular polarization. Furthermore, large-diameter nanotubes promoted nuclear pore deformation and YAP nuclear translocation, leading to enhanced osteogenic differentiation both in vitro and in vivo. Together, our findings suggest that nanotube diameter-dependent geometry regulates the spatial presentation of adhesive ligands and subsequently influences FA maturation, cellular polarization, and YAP-associated mechanotransduction. This study provides mechanistic insight into how implant nanotopography modulates osteogenic responses and offers a theoretical basis for the rational design of osteogenic implant surfaces.

Authors

Publication Details

Journal
Bioactive Materials
Published
2026-07-23
DOI
https://doi.org/10.1016/j.bioactmat.2026.07.031
Primary Topic
Cell Adhesion Molecules Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cells perceive the distribution differences of adhesion ligands and consequently establish cellular polarization to regulate osteogenic differentiation

Jianhao Huang, Qing Jiang, Tailin Guo, Jie Weng et al.
Bioactive Materials
Cell Adhesion Molecules Research
article

Cells perceive the distribution differences of adhesion ligands and consequently establish cellular polarization to regulate osteogenic differentiation

Jianhao Huang, Qing Jiang, Tailin Guo, Jie Weng, Qiting Ge, Jinsheng Li, Jingyi Sheng, Zhihong Xu, Guowen Duan, Ning Gu, Jie Cui, Jizi Liu, Liming Yang, Ming Yang, Tao Shen, Keke Huang
article en

Abstract

Engineering implant topography has emerged as a promising strategy to promote bone regeneration in complex fractures and large bone defects. Among such topographies, TiO 2 nanotubes serve as a model topography and have been shown, within a certain range, to positively regulate osteogenic differentiation through diameter-dependent effects. However, the underlying mechanisms remains fragmentary. Here, we revealed how cells perceived nanotube interfaces and identified the intracellular force-based mechanotransduction that arose from interface perception. We unexpectedly found that cellular perception of nanotube interfaces depended on diameter-associated topographical cues that induced differential distribution of adhesive ligands. Cells engaged these adhesive ligands to modulate focal adhesion (FA) organization, with small and many FAs forming on the small-diameter nanotubes (30 nm), whereas fewer but larger FAs formed on the large-diameter nanotubes (100 nm). Fewer but larger FAs regulated cytoskeletal assembly, generating greater intracellular force and enhancing cellular polarization. Furthermore, large-diameter nanotubes promoted nuclear pore deformation and YAP nuclear translocation, leading to enhanced osteogenic differentiation both in vitro and in vivo. Together, our findings suggest that nanotube diameter-dependent geometry regulates the spatial presentation of adhesive ligands and subsequently influences FA maturation, cellular polarization, and YAP-associated mechanotransduction. This study provides mechanistic insight into how implant nanotopography modulates osteogenic responses and offers a theoretical basis for the rational design of osteogenic implant surfaces.

Bioactive MaterialsVol. 66
Openalex Percentile: Top 10%
Cell Adhesion Molecules Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.