Real‐World Effectiveness and Safety of a Tubeless Automated Insulin Delivery System With an Adaptive Control Algorithm ( <scp>APGO</scp> ) in Children and Adolescents With Type 1 Diabetes: A Multicentre Observational Study

AIM: Automated insulin delivery (AID) systems improve glycaemic outcomes in Type 1 diabetes; however, paediatric real-world data on newly introduced tubeless AID systems remain limited. We aimed to provide the first clinical evaluation of the A8 TouchCare Nano AID system with the APGO algorithm in children and adolescents with Type 1 diabetes. MATERIALS AND METHODS: In this prospective observational study, children and adolescents initiating TouchCare Nano AID therapy were followed for 6 months. Continuous glucose monitoring metrics were assessed at baseline and 1, 3 and 6 months. The primary outcome was change in time in range (TIR, 70-180 mg/dL). Secondary outcomes included time in tight range (TiTR, 70-140 mg/dL), time above and below range, glucose variability, insulin dose, achievement of ISPAD glycaemic targets and safety. HbA1c was measured at baseline, 3 and 6 months. RESULTS: Seventy-six participants (mean age 13.3 ± 3.2 years) completed follow-up. Mean TIR increased from 59.0% ± 15.6% at baseline to 74.2% ± 8.9% at 1 month and remained significantly higher at 3 and 6 months (all p < 0.05). TiTR significantly improved, whilst time above range decreased and time below range remained stable. More than half of participants achieved the ISPAD target of TIR > 70% at 6 months. Mean sensor glucose and glucose variability declined, and HbA1c decreased from 7.4% ± 0.8% to 6.9% ± 0.7% at 3 and 6 months (all p < 0.05). No episodes of severe hypoglycaemia or diabetic ketoacidosis were observed. CONCLUSIONS: In routine paediatric care, use of this tubeless AID system was associated with rapid and sustained improvements in glycaemic control without increased hypoglycaemia. TRIAL REGISTRATION: Clinicaltrials.gov: NCT07425912.

Authors

Institutions

Publication Details

Journal
Diabetes Obesity and Metabolism
Published
2026-07-23
DOI
https://doi.org/10.1111/dom.71101
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real‐World Effectiveness and Safety of a Tubeless Automated Insulin Delivery System With an Adaptive Control Algorithm ( APGO ) in Children and Adolescents With Type 1 Diabetes: A Multicentre Observational Study

Assunta Serena Rollato, Dario Iafusco, Adele Figuccia, Barbara Piccini et al.
Diabetes Obesity and Metabolism
Diabetes Management and Research
article

Real‐World Effectiveness and Safety of a Tubeless Automated Insulin Delivery System With an Adaptive Control Algorithm ( APGO ) in Children and Adolescents With Type 1 Diabetes: A Multicentre Observational Study

Assunta Serena Rollato, Dario Iafusco, Adele Figuccia, Barbara Piccini, Sonia Toni, Angela Zanfardino, Antonietta Chianese, Giorgia Ippolito, Annalisa Giulia Ferlito, Emanuele Miraglia del Giudice
article en

Abstract

AIM: Automated insulin delivery (AID) systems improve glycaemic outcomes in Type 1 diabetes; however, paediatric real-world data on newly introduced tubeless AID systems remain limited. We aimed to provide the first clinical evaluation of the A8 TouchCare Nano AID system with the APGO algorithm in children and adolescents with Type 1 diabetes. MATERIALS AND METHODS: In this prospective observational study, children and adolescents initiating TouchCare Nano AID therapy were followed for 6 months. Continuous glucose monitoring metrics were assessed at baseline and 1, 3 and 6 months. The primary outcome was change in time in range (TIR, 70-180 mg/dL). Secondary outcomes included time in tight range (TiTR, 70-140 mg/dL), time above and below range, glucose variability, insulin dose, achievement of ISPAD glycaemic targets and safety. HbA1c was measured at baseline, 3 and 6 months. RESULTS: Seventy-six participants (mean age 13.3 ± 3.2 years) completed follow-up. Mean TIR increased from 59.0% ± 15.6% at baseline to 74.2% ± 8.9% at 1 month and remained significantly higher at 3 and 6 months (all p < 0.05). TiTR significantly improved, whilst time above range decreased and time below range remained stable. More than half of participants achieved the ISPAD target of TIR > 70% at 6 months. Mean sensor glucose and glucose variability declined, and HbA1c decreased from 7.4% ± 0.8% to 6.9% ± 0.7% at 3 and 6 months (all p < 0.05). No episodes of severe hypoglycaemia or diabetic ketoacidosis were observed. CONCLUSIONS: In routine paediatric care, use of this tubeless AID system was associated with rapid and sustained improvements in glycaemic control without increased hypoglycaemia. TRIAL REGISTRATION: Clinicaltrials.gov: NCT07425912.

Diabetes Obesity and Metabolism
Regione Campania (IT), Meyer Children's Hospital (IT), University of Palermo (IT)
Openalex Percentile: Top 9%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.