Single-port robotic areolar thyroidectomy: technical feasibility and clinical outcomes of 64 consecutive cases

Single-port robotic areolar (SPRA) thyroidectomy is a recent refinement of the bilateral axillo-breast approach (BABA) that employs the da Vinci single-port system to establish a single-trajectory corridor while preserving a scarless neck. However, clinical data remain limited. The present study evaluated whether SPRA is clinically feasible and technically safe. This retrospective study analyzed 64 consecutive women who underwent SPRA at a single center between March and September 2025. We compared flap dissection extent between SPRA and BABA using a standardized grid-based model and analyzed perioperative outcomes. Console time was analyzed by laterality, body mass index (BMI), and learning phase via cumulative sum (CUSUM) analysis. Less-than-total and total thyroidectomy were performed in 59 (92.2%) and 5 (7.8%) patients, respectively. The mean console time was 69.3 ± 27.4 min and did not differ significantly by laterality or correlate with BMI. CUSUM analysis showed an inflection point at case 15; the late phase (cases 16-60) had significantly shorter console times than the early phase (cases 1-15) (62.9 vs. 82.4 min; median difference, 17.0 min; p = 0.017). Modeled flap dissection area was approximately 28% smaller for SPRA than for BABA. No conversions occurred. Transient vocal cord palsy affected six patients (9.4%) and transient hypoparathyroidism affected one (20% of total thyroidectomies), with no permanent complications. SPRA demonstrated a smaller estimated flap dissection, consistent operative performance, and early stabilization of console time. These findings support SPRA as a safe and feasible integrated platform for remote-access thyroidectomy.

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2026-08-28
DOI
https://doi.org/10.1007/s11701-026-03872-x
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-port robotic areolar thyroidectomy: technical feasibility and clinical outcomes of 64 consecutive cases

Jaewan Jeon, Dohoon Koo, K H Lee, Soohyeon Lee et al.
Journal of Robotic Surgery
Thyroid and Parathyroid Surgery
article

Single-port robotic areolar thyroidectomy: technical feasibility and clinical outcomes of 64 consecutive cases

Jaewan Jeon, Dohoon Koo, K H Lee, Soohyeon Lee, Dongsik Bae, Myunghan Yu
article en

Abstract

Single-port robotic areolar (SPRA) thyroidectomy is a recent refinement of the bilateral axillo-breast approach (BABA) that employs the da Vinci single-port system to establish a single-trajectory corridor while preserving a scarless neck. However, clinical data remain limited. The present study evaluated whether SPRA is clinically feasible and technically safe. This retrospective study analyzed 64 consecutive women who underwent SPRA at a single center between March and September 2025. We compared flap dissection extent between SPRA and BABA using a standardized grid-based model and analyzed perioperative outcomes. Console time was analyzed by laterality, body mass index (BMI), and learning phase via cumulative sum (CUSUM) analysis. Less-than-total and total thyroidectomy were performed in 59 (92.2%) and 5 (7.8%) patients, respectively. The mean console time was 69.3 ± 27.4 min and did not differ significantly by laterality or correlate with BMI. CUSUM analysis showed an inflection point at case 15; the late phase (cases 16-60) had significantly shorter console times than the early phase (cases 1-15) (62.9 vs. 82.4 min; median difference, 17.0 min; p = 0.017). Modeled flap dissection area was approximately 28% smaller for SPRA than for BABA. No conversions occurred. Transient vocal cord palsy affected six patients (9.4%) and transient hypoparathyroidism affected one (20% of total thyroidectomies), with no permanent complications. SPRA demonstrated a smaller estimated flap dissection, consistent operative performance, and early stabilization of console time. These findings support SPRA as a safe and feasible integrated platform for remote-access thyroidectomy.

Journal of Robotic SurgeryVol. 20(1)
Inje University Haeundae Paik Hospital (KR)
Good health and well-being
Openalex Percentile: Top 23%
Thyroid and Parathyroid Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.