Clinically aligned artificial intelligence for glaucoma diagnosis: enhancing retinal nerve fibre layer interpretation from fundus images

BACKGROUND/OBJECTIVES: This study aimed to develop an interpretable artificial intelligence (AI) screening system that replicates a specialist's evaluation of fundus photographs. The system analyses three signs: visible retinal nerve fibre layer (RNFL) defects (as observed on fundus photography, not OCT-based measurement), vertical cup-to-disc ratio (VCDR) and rim-to-disc ratio (RDR). SUBJECTS/METHODS: A total of 773 fundus images from the independent test cohort were annotated by three fellowship-trained glaucoma specialists, followed by repeated consensus meetings to improve annotation consistency. Two models were trained on the development cohort: an EfficientNet-B4 classifier for RNFL and a U-Net with an EfficientNet-B4 encoder for optic disc/cup (OD/OC) segmentation. During the testing phase, a referral was triggered whenever a feature was classified as abnormal, with the system explicitly reporting the specific sign that prompted the referral decision. RESULTS: Among the 773 expert-annotated cases, 749 were included in the analysis after excluding low-quality or insufficient-information images (AI drop rate: 3.1%). The final independent test cohort comprised 268 referral and 481 non-referral cases, providing a basis for evaluation. The combined model achieved a sensitivity of 0.903 (95% confidence interval [CI], 0.868-0.938), specificity of 0.821 (95% CI, 0.787-0.855) and a positive predictive value (PPV) of 0.738 (95% CI, 0.690-0.785). The system captured complementary aspects of glaucomatous optic neuropathy that are often missed by single-feature approaches. CONCLUSIONS: Consensus-based annotation, combined with lesion-level modelling, enhances alignment with clinical reasoning. By providing an explicit referral rationale, the system fosters trust in AI-assisted glaucoma screening and facilitates adoption in clinical settings.

Authors

Institutions

Publication Details

Journal
Eye
Published
2026-07-23
DOI
https://doi.org/10.1038/s41433-026-04758-w
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinically aligned artificial intelligence for glaucoma diagnosis: enhancing retinal nerve fibre layer interpretation from fundus images

Yi-Ching Shao, Chien‐Hung Li, Yun Hsia, Chang Py et al.
Eye
Retinal Imaging and Analysis
article

Clinically aligned artificial intelligence for glaucoma diagnosis: enhancing retinal nerve fibre layer interpretation from fundus images

Yi-Ching Shao, Chien‐Hung Li, Yun Hsia, Chang Py, Yijin Huang, Bo‐I Kuo, Sunny Chung, Jehn‐Yu Huang, Ming-Chi Kuo, Chien‐Chia Su, Pai‐Huei Peng, Chia-En Lien, Wei-Hao Chang, Kai-Cheng Hsu
article en

Abstract

BACKGROUND/OBJECTIVES: This study aimed to develop an interpretable artificial intelligence (AI) screening system that replicates a specialist's evaluation of fundus photographs. The system analyses three signs: visible retinal nerve fibre layer (RNFL) defects (as observed on fundus photography, not OCT-based measurement), vertical cup-to-disc ratio (VCDR) and rim-to-disc ratio (RDR). SUBJECTS/METHODS: A total of 773 fundus images from the independent test cohort were annotated by three fellowship-trained glaucoma specialists, followed by repeated consensus meetings to improve annotation consistency. Two models were trained on the development cohort: an EfficientNet-B4 classifier for RNFL and a U-Net with an EfficientNet-B4 encoder for optic disc/cup (OD/OC) segmentation. During the testing phase, a referral was triggered whenever a feature was classified as abnormal, with the system explicitly reporting the specific sign that prompted the referral decision. RESULTS: Among the 773 expert-annotated cases, 749 were included in the analysis after excluding low-quality or insufficient-information images (AI drop rate: 3.1%). The final independent test cohort comprised 268 referral and 481 non-referral cases, providing a basis for evaluation. The combined model achieved a sensitivity of 0.903 (95% confidence interval [CI], 0.868-0.938), specificity of 0.821 (95% CI, 0.787-0.855) and a positive predictive value (PPV) of 0.738 (95% CI, 0.690-0.785). The system captured complementary aspects of glaucomatous optic neuropathy that are often missed by single-feature approaches. CONCLUSIONS: Consensus-based annotation, combined with lesion-level modelling, enhances alignment with clinical reasoning. By providing an explicit referral rationale, the system fosters trust in AI-assisted glaucoma screening and facilitates adoption in clinical settings.

Eye
National Taiwan University (TW), China Medical University (TW), Far Eastern Memorial Hospital (TW), China Medical University Hospital (TW), National Taiwan University Hospital (TW), Acer (Taiwan) (TW)
Peace, Justice and strong institutions
Openalex Percentile: Top 9%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.