Left–Right Consistency and Quantification of Craniofacial Asymmetry by Two Fully Automatic AI-Powered Three-Dimensional Cephalometry Systems on CBCT

Background/Objectives: Automatic three-dimensional (3D) cephalometry on cone beam computed tomography (CBCT) is increasingly used in orthodontic and orthognathic practice, but whether fully automatic systems reproduce bilateral measurements with equal fidelity on both sides, and whether the right–left difference they report can be trusted as a clinical measure of asymmetry, has not been studied systematically. This study aimed to quantify side-specific agreement and asymmetry quantification fidelity of two commercial AI cephalometry systems against calibrated manual 3D tracing. Methods: Thirty-one CBCT scans were analysed by calibrated manual tracing (InVivo software), an integrated AI module (AI InVivo), and a cloud-based system (Diagnocat). Side-specific agreement was quantified using the two-way random effects intraclass correlation coefficient [ICC(2,1)], Bland–Altman analysis, and two one-sided equivalence tests (±2°/±2 mm). Asymmetry fidelity was assessed by ICC of the automatic right–left difference (Δ = R − L) against the manual Δ, Pearson correlation, and sensitivity/specificity for detecting clinically relevant asymmetry. Results: Per-side agreement closely mirrored overall accuracy; any systematic error was applied almost equally to both sides (bias difference ≤0.3° or ≤0.9 mm between sides). The mandibular plane angle achieved excellent ICC (0.95–0.97) and equivalence on both sides for both systems. The gonial angle was equivalent for AI InVivo (ICC 0.92–0.93) but not for Diagnocat (ICC 0.40; bias −6.95° and −6.97° on the right and left, respectively). Asymmetry agreement was generally weaker than per-side accuracy. Diagnocat showed no correlation with manual gonial asymmetry (ICC −0.12), while AI InVivo demonstrated poor agreement for body length asymmetry (ICC 0.18). Both systems under-detected clinically relevant gonial asymmetry (sensitivity 0.00–0.17), with errors predominantly in the false-negative direction. Conclusions: Fully automatic AI-powered 3D cephalometry applies systematic errors symmetrically to both sides, so per-side accuracy holds equally for right and left measurements. However, asymmetry fidelity is a separate, more demanding property that does not follow from absolute accuracy and remains unreliable for landmark-sensitive parameters such as the gonial angle. Clinician verification is required before automatic analysis is used for asymmetry assessment.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-07-23
DOI
https://doi.org/10.3390/diagnostics16152306
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Left–Right Consistency and Quantification of Craniofacial Asymmetry by Two Fully Automatic AI-Powered Three-Dimensional Cephalometry Systems on CBCT

Oleg Mordanov, З. С. Хабадзе, Ahmad Wehbe
Diagnostics
Orthodontics and Dentofacial Orthopedics
article

Left–Right Consistency and Quantification of Craniofacial Asymmetry by Two Fully Automatic AI-Powered Three-Dimensional Cephalometry Systems on CBCT

Oleg Mordanov, З. С. Хабадзе, Ahmad Wehbe
article en

Abstract

Background/Objectives: Automatic three-dimensional (3D) cephalometry on cone beam computed tomography (CBCT) is increasingly used in orthodontic and orthognathic practice, but whether fully automatic systems reproduce bilateral measurements with equal fidelity on both sides, and whether the right–left difference they report can be trusted as a clinical measure of asymmetry, has not been studied systematically. This study aimed to quantify side-specific agreement and asymmetry quantification fidelity of two commercial AI cephalometry systems against calibrated manual 3D tracing. Methods: Thirty-one CBCT scans were analysed by calibrated manual tracing (InVivo software), an integrated AI module (AI InVivo), and a cloud-based system (Diagnocat). Side-specific agreement was quantified using the two-way random effects intraclass correlation coefficient [ICC(2,1)], Bland–Altman analysis, and two one-sided equivalence tests (±2°/±2 mm). Asymmetry fidelity was assessed by ICC of the automatic right–left difference (Δ = R − L) against the manual Δ, Pearson correlation, and sensitivity/specificity for detecting clinically relevant asymmetry. Results: Per-side agreement closely mirrored overall accuracy; any systematic error was applied almost equally to both sides (bias difference ≤0.3° or ≤0.9 mm between sides). The mandibular plane angle achieved excellent ICC (0.95–0.97) and equivalence on both sides for both systems. The gonial angle was equivalent for AI InVivo (ICC 0.92–0.93) but not for Diagnocat (ICC 0.40; bias −6.95° and −6.97° on the right and left, respectively). Asymmetry agreement was generally weaker than per-side accuracy. Diagnocat showed no correlation with manual gonial asymmetry (ICC −0.12), while AI InVivo demonstrated poor agreement for body length asymmetry (ICC 0.18). Both systems under-detected clinically relevant gonial asymmetry (sensitivity 0.00–0.17), with errors predominantly in the false-negative direction. Conclusions: Fully automatic AI-powered 3D cephalometry applies systematic errors symmetrically to both sides, so per-side accuracy holds equally for right and left measurements. However, asymmetry fidelity is a separate, more demanding property that does not follow from absolute accuracy and remains unreliable for landmark-sensitive parameters such as the gonial angle. Clinician verification is required before automatic analysis is used for asymmetry assessment.

DiagnosticsVol. 16(15)
Peoples' Friendship University of Russia (RU)
No poverty
Openalex Percentile: Top 7%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.