Precision of virtual surgical planning employing screw-holes locator and patient-specific implants versus conventional plate osteosynthesis for parasymphyseal mandibular fracture: a double-blinded randomized control trial

Abstract Background Conventional plate osteosynthesis is the corner stone for management of displaced parasymphyseal mandibular fractures that necessitate open reduction and internal fixation (ORIF). Yet, the conventional workflow is labor-intensive, time consuming and limited by variable reduction accuracy as it relies solely on surgeon experience. Recently, various novel computer-guided techniques have been introduced for mandibular fracture repair, hiring surgical guides of diverse designs and strategies. These techniques served as a substitute for the conventional treatment modalities, offering improved precision, speed and reproducibility. Therefore, this randomized controlled trial (RCT) compares the overall precision of this distinct complete computer-guided virtual surgical planning (VSP) protocol as a whole, employing screw-holes locator and custom-made plates versus the conventional workflow for parasymphyseal mandibular fracture repair. Methods Twenty-six cases presented with uncomminuted parasymphyseal mandibular fracture were enrolled and randomized into two groups. The interventional group underwent ORIF utilizing a screw-hole locator and custom-made plates, while the control group utilized ready-made mini-plates for ORIF. In both groups, virtual surgical planning of the fractured mandible was accomplished, creating a virtual reduced model by Mimics software aided by preoperative computer tomography (CT) scan. Then, three-dimensional model derived from the postoperative CT scan was superimposed onto the VSP reduced model. Linear deviations between predefined dental and bony landmarks to established anatomical planes were measured and underwent statistical analysis. Results The actual postoperative mandibular model in the computer-guided group demonstrated negligible deviation from the VSP model. While the conventional group revealed considerably greater deviation. The average deviation of the bony landmarks was 0.044 ± 0.14 mm for the intervention group versus 0.69 ± 0.5 mm for the control group ( p < 0.001). The average deviation of the dental landmarks was 0.04 ± 0.13 mm for the intervention group versus 0.47 ± 0.33 mm for the control group ( p < 0.001). The average surgical time of the intervention group was 1.46 ± 0.18 h versus 1.80 ± 0.34 h for the control group ( p = 0.004), with the intergroup difference being statistically significant. Conclusions The integration of screw-holes locator and patient-specific implants (PSI) have improved anatomical reduction precision, facilitated reestablishment of the patient’s native occlusion and ensured more standardized reproducible outcomes, especially beneficial for less experienced surgeons. Trial registration The study is a randomized control trial, registered at ClinicalTrials.gov Protocol Registration and Results System Receipt, NCT05647460, Data: 2022–12-05.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-07-23
DOI
https://doi.org/10.1186/s12903-026-09303-5
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precision of virtual surgical planning employing screw-holes locator and patient-specific implants versus conventional plate osteosynthesis for parasymphyseal mandibular fracture: a double-blinded randomized control trial

Mohammed Omara, Hussein Hatem, Ahmed Abdellatif, Mona Elhadidy
BMC Oral Health
Facial Trauma and Fracture Management
article

Precision of virtual surgical planning employing screw-holes locator and patient-specific implants versus conventional plate osteosynthesis for parasymphyseal mandibular fracture: a double-blinded randomized control trial

Mohammed Omara, Hussein Hatem, Ahmed Abdellatif, Mona Elhadidy
article en

Abstract

Abstract Background Conventional plate osteosynthesis is the corner stone for management of displaced parasymphyseal mandibular fractures that necessitate open reduction and internal fixation (ORIF). Yet, the conventional workflow is labor-intensive, time consuming and limited by variable reduction accuracy as it relies solely on surgeon experience. Recently, various novel computer-guided techniques have been introduced for mandibular fracture repair, hiring surgical guides of diverse designs and strategies. These techniques served as a substitute for the conventional treatment modalities, offering improved precision, speed and reproducibility. Therefore, this randomized controlled trial (RCT) compares the overall precision of this distinct complete computer-guided virtual surgical planning (VSP) protocol as a whole, employing screw-holes locator and custom-made plates versus the conventional workflow for parasymphyseal mandibular fracture repair. Methods Twenty-six cases presented with uncomminuted parasymphyseal mandibular fracture were enrolled and randomized into two groups. The interventional group underwent ORIF utilizing a screw-hole locator and custom-made plates, while the control group utilized ready-made mini-plates for ORIF. In both groups, virtual surgical planning of the fractured mandible was accomplished, creating a virtual reduced model by Mimics software aided by preoperative computer tomography (CT) scan. Then, three-dimensional model derived from the postoperative CT scan was superimposed onto the VSP reduced model. Linear deviations between predefined dental and bony landmarks to established anatomical planes were measured and underwent statistical analysis. Results The actual postoperative mandibular model in the computer-guided group demonstrated negligible deviation from the VSP model. While the conventional group revealed considerably greater deviation. The average deviation of the bony landmarks was 0.044 ± 0.14 mm for the intervention group versus 0.69 ± 0.5 mm for the control group ( p < 0.001). The average deviation of the dental landmarks was 0.04 ± 0.13 mm for the intervention group versus 0.47 ± 0.33 mm for the control group ( p < 0.001). The average surgical time of the intervention group was 1.46 ± 0.18 h versus 1.80 ± 0.34 h for the control group ( p = 0.004), with the intergroup difference being statistically significant. Conclusions The integration of screw-holes locator and patient-specific implants (PSI) have improved anatomical reduction precision, facilitated reestablishment of the patient’s native occlusion and ensured more standardized reproducible outcomes, especially beneficial for less experienced surgeons. Trial registration The study is a randomized control trial, registered at ClinicalTrials.gov Protocol Registration and Results System Receipt, NCT05647460, Data: 2022–12-05.

BMC Oral HealthVol. 26(1)
Cairo University (EG)
Cairo University
Decent work and economic growth
Openalex Percentile: Top 7%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.