Multimodal learning for clinically consistent RGP fitting in keratoconus

Abstract Keratoconus is a progressive corneal disorder characterized by highly heterogeneous corneal morphology, which makes rigid gas permeable (RGP) lens fitting strongly dependent on clinician experience and iterative trial processes. This procedure is often time-consuming and may lead to patient discomfort. Existing artificial intelligence approaches typically rely on either corneal imaging or clinical parameters alone, limiting their ability to capture the complex coupling relationships underlying lens fitting. In this study, we propose a unified multimodal deep learning framework, termed CME-Net, to jointly predict key RGP fitting parameters, including base curve (BC), lens diameter (Dia), and fitting strategy. The framework integrates boundary artifact suppression preprocessing with a dual-branch feature extraction network and employs structured multimodal feature fusion to explicitly model interactions between corneal topography and clinical indicators. A unified output head enables collaborative multi-task inference. By integrating complementary information from multiple data sources within a unified framework, the proposed method enables a more comprehensive characterization of corneal morphology and its clinical implications. The proposed method was developed and evaluated using a labeled analytic cohort of 368 keratoconus eyes with complete usable reference labels, derived from a retrospective cohort of 515 eyes collected at the Eye Center of the Second Affiliated Hospital, Zhejiang University School of Medicine. Under the held-out evaluation protocol, CME-Net achieved mean absolute errors of 0.2178 mm for BC and 0.1250 mm for Dia. Compared with the strongest unimodal baseline, the proposed framework reduced the Total MAE by approximately 15%. These results suggest that multimodal integration can enhance the accuracy and consistency of RGP lens fitting prediction. The proposed framework may provide supportive initial fitting guidance for personalized RGP fitting in keratoconus, while clinician oversight remains necessary, particularly for boundary or high-error cases.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-07-23
DOI
https://doi.org/10.1038/s41598-026-63209-4
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multimodal learning for clinically consistent RGP fitting in keratoconus

Yingying Zhao, Peifang Xu, Gangyong Jia, J P Ye et al.
Scientific Reports
Corneal surgery and disorders
article

Multimodal learning for clinically consistent RGP fitting in keratoconus

Yingying Zhao, Peifang Xu, Gangyong Jia, J P Ye, Hongbiao Xie, Lin An
article en

Abstract

Abstract Keratoconus is a progressive corneal disorder characterized by highly heterogeneous corneal morphology, which makes rigid gas permeable (RGP) lens fitting strongly dependent on clinician experience and iterative trial processes. This procedure is often time-consuming and may lead to patient discomfort. Existing artificial intelligence approaches typically rely on either corneal imaging or clinical parameters alone, limiting their ability to capture the complex coupling relationships underlying lens fitting. In this study, we propose a unified multimodal deep learning framework, termed CME-Net, to jointly predict key RGP fitting parameters, including base curve (BC), lens diameter (Dia), and fitting strategy. The framework integrates boundary artifact suppression preprocessing with a dual-branch feature extraction network and employs structured multimodal feature fusion to explicitly model interactions between corneal topography and clinical indicators. A unified output head enables collaborative multi-task inference. By integrating complementary information from multiple data sources within a unified framework, the proposed method enables a more comprehensive characterization of corneal morphology and its clinical implications. The proposed method was developed and evaluated using a labeled analytic cohort of 368 keratoconus eyes with complete usable reference labels, derived from a retrospective cohort of 515 eyes collected at the Eye Center of the Second Affiliated Hospital, Zhejiang University School of Medicine. Under the held-out evaluation protocol, CME-Net achieved mean absolute errors of 0.2178 mm for BC and 0.1250 mm for Dia. Compared with the strongest unimodal baseline, the proposed framework reduced the Total MAE by approximately 15%. These results suggest that multimodal integration can enhance the accuracy and consistency of RGP lens fitting prediction. The proposed framework may provide supportive initial fitting guidance for personalized RGP fitting in keratoconus, while clinician oversight remains necessary, particularly for boundary or high-error cases.

Scientific Reports
Zhejiang Lab (CN), Second Affiliated Hospital of Zhejiang University (CN), Hangzhou Dianzi University (CN)
Zhejiang University, Department of Education of Zhejiang Province
Openalex Percentile: Top 9%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.