Experimental estimation of extremity doses from handheld XRF devices during radiation exposure incidents

This study experimentally evaluates extremity doses from unintentional exposure emitted by handheld X-ray fluorescence (XRF) analyzers. Although handheld XRF devices are widely used for material analysis, quantitative assessments of unintentional exposure remain limited. Mockup experiments were conducted using a Thermo Scientific NITON XLt 797 analyzer and a polymethyl methacrylate hand phantom equipped with radiophotoluminescent glass dosemeters (GD-302M). Spectrometric measurements were performed with a CdTe detector, and photon fluence spectra were unfolded using the MAXED code with Particle and Heavy Ion Transport code System-generated response functions. The mean X-ray energy was 28.4 ± 0.03 keV, with characteristic molybdenum peaks at ~17.5 keV (Kα) and 19.6 keV (Kβ). For a typical 30-s analysis, the estimated personal dose equivalent Hp(0.07) at the point of contact was ~95 μSv. The Hp(0.07) on the dorsal side was roughly one-fifth of the palmar dose. Ambient dose equivalent rates measured directly from the XRF device may reach high enough to set radiation-controlled areas, underscoring the need for strict handling protocols. These findings demonstrate the importance of radiological protection education and awareness when using handheld XRF devices.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2026-07-23
DOI
https://doi.org/10.1093/rpd/ncag075
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental estimation of extremity doses from handheld XRF devices during radiation exposure incidents

Munehiko Kowatari, Yoshihiko Tanimura, Tomoya Tsuji, N Kataoka et al.
Radiation Protection Dosimetry
Radiation Dose and Imaging
article

Experimental estimation of extremity doses from handheld XRF devices during radiation exposure incidents

Munehiko Kowatari, Yoshihiko Tanimura, Tomoya Tsuji, N Kataoka, M Kobayashi
article en

Abstract

This study experimentally evaluates extremity doses from unintentional exposure emitted by handheld X-ray fluorescence (XRF) analyzers. Although handheld XRF devices are widely used for material analysis, quantitative assessments of unintentional exposure remain limited. Mockup experiments were conducted using a Thermo Scientific NITON XLt 797 analyzer and a polymethyl methacrylate hand phantom equipped with radiophotoluminescent glass dosemeters (GD-302M). Spectrometric measurements were performed with a CdTe detector, and photon fluence spectra were unfolded using the MAXED code with Particle and Heavy Ion Transport code System-generated response functions. The mean X-ray energy was 28.4 ± 0.03 keV, with characteristic molybdenum peaks at ~17.5 keV (Kα) and 19.6 keV (Kβ). For a typical 30-s analysis, the estimated personal dose equivalent Hp(0.07) at the point of contact was ~95 μSv. The Hp(0.07) on the dorsal side was roughly one-fifth of the palmar dose. Ambient dose equivalent rates measured directly from the XRF device may reach high enough to set radiation-controlled areas, underscoring the need for strict handling protocols. These findings demonstrate the importance of radiological protection education and awareness when using handheld XRF devices.

Radiation Protection Dosimetry
Japan Atomic Energy Agency (JP), National Institutes for Quantum Science and Technology (JP), Tokyo Metropolitan Industrial Technology Research Institute (JP)
Ministry of Health, Labour and Welfare
Quality Education
Openalex Percentile: Top 9%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental estimation of extremity doses from handheld XRF devices during radiation exposure incidents — Munehiko Kowatari, Yoshihiko Tanimura, et al. · Radiation Protection Dosimetry (2026) | TGRS Research Map | TGRS