CFD study of the influence of inlet geometry in non-premixed microreactors on the thermal performance of catalytic hydrogen combustion

Catalytic hydrogen combustion (CHC) provides stable, low-temperature heat release in compact microreactors without a freely propagating flame. In non-premixed catalytic reactors, inlet geometry affects near-wall reactant delivery, reaction-zone distribution, and wall heat extraction. Because these coupled transport-reaction effects are difficult to resolve experimentally, three-dimensional computational fluid dynamics simulations with detailed platinum surface kinetics and conjugate heat transfer were performed for a CHC microchannel reactor in which inlet geometries were explicitly resolved under non-premixed reactant supply. The effects of nozzle placement, nozzle length, premixing length, and porous-layer-assisted injection were evaluated using hydrogen conversion, average wall temperature, wall-temperature non-uniformity, pressure drop, total wall heat-transfer rate, and wall heat-transfer efficiency. The results show that shifting the nozzle upstream and introducing a finite premixing section redistribute the reaction zone, markedly reduce wall-temperature non-uniformity relative to the extreme inlet arrangements under non-premixed operation, and maintain high hydrogen conversion. Under the reference operating condition considered in this study, the 3 mm / 3 mm solid-nozzle configuration provided the most favorable thermal-hydraulic balance within the explored solid-nozzle design space. Relative to the corresponding solid-nozzle inlet case, the porous-layer-assisted inlet was associated with enhanced hydrogen depletion near the catalytic wall, an increase of about 40 K in average wall temperature, and the highest wall heat-transfer rate of about 83 W together with a wall heat-transfer efficiency of 57.65%. These findings highlight the importance of near-wall transport and reaction-zone redistribution for improving reactor-level wall heat extraction and thermal-hydraulic performance in non-premixed CHC microreactors under the modeled boundary conditions.

Authors

Institutions

Publication Details

Journal
Fuel
Published
2026-07-23
DOI
https://doi.org/10.1016/j.fuel.2026.140741
Primary Topic
Combustion and flame dynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CFD study of the influence of inlet geometry in non-premixed microreactors on the thermal performance of catalytic hydrogen combustion

Baiqian Dai, Shirong Guo, Jianglong Yu, Moshan Li et al.
Fuel
Combustion and flame dynamics
article

CFD study of the influence of inlet geometry in non-premixed microreactors on the thermal performance of catalytic hydrogen combustion

Baiqian Dai, Shirong Guo, Jianglong Yu, Moshan Li, Yuhang Qiu, Mengting Wang, Yunze Hui, Sankar Bhattacharya, Pengxiang Zhao
article en

Abstract

Catalytic hydrogen combustion (CHC) provides stable, low-temperature heat release in compact microreactors without a freely propagating flame. In non-premixed catalytic reactors, inlet geometry affects near-wall reactant delivery, reaction-zone distribution, and wall heat extraction. Because these coupled transport-reaction effects are difficult to resolve experimentally, three-dimensional computational fluid dynamics simulations with detailed platinum surface kinetics and conjugate heat transfer were performed for a CHC microchannel reactor in which inlet geometries were explicitly resolved under non-premixed reactant supply. The effects of nozzle placement, nozzle length, premixing length, and porous-layer-assisted injection were evaluated using hydrogen conversion, average wall temperature, wall-temperature non-uniformity, pressure drop, total wall heat-transfer rate, and wall heat-transfer efficiency. The results show that shifting the nozzle upstream and introducing a finite premixing section redistribute the reaction zone, markedly reduce wall-temperature non-uniformity relative to the extreme inlet arrangements under non-premixed operation, and maintain high hydrogen conversion. Under the reference operating condition considered in this study, the 3 mm / 3 mm solid-nozzle configuration provided the most favorable thermal-hydraulic balance within the explored solid-nozzle design space. Relative to the corresponding solid-nozzle inlet case, the porous-layer-assisted inlet was associated with enhanced hydrogen depletion near the catalytic wall, an increase of about 40 K in average wall temperature, and the highest wall heat-transfer rate of about 83 W together with a wall heat-transfer efficiency of 57.65%. These findings highlight the importance of near-wall transport and reaction-zone redistribution for improving reactor-level wall heat extraction and thermal-hydraulic performance in non-premixed CHC microreactors under the modeled boundary conditions.

FuelVol. 429
Jimei University (CN), Nantong University (CN), Nantong Science and Technology Bureau (CN), Suzhou Research Institute (CN), Wuhan University of Science and Technology (CN), Monash University (AU)
Monash University, National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 11%
Combustion and flame dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.