Finite Element Implementation, Validation, and Interpretation of a Solitary Wave Tonometer Using Hyper-Viscoelastic Corneal Models

Abstract Glaucoma is an age-related disease whose progression can be slowed by managing intraocular pressure (IOP). While Goldmann applanation remains the gold standard for IOP measurement, it provides only single-point readings that may fail to capture circadian fluctuations and sporadic pressure surges. This limitation can be addressed with a patient-operated device capable of continuous monitoring or frequent measurements anywhere, anytime. Our group has recently proposed a new tonometer based on the propagation of highly nonlinear solitary waves within a chain of particles. An incident solitary wave (ISW) is induced at one end of the chain. Once the ISW reaches the opposite end and in dry contact with the eye to be evaluated, a primary and a secondary solitary wave (PSW and SSW) rebound. The waves are detected by a sensing coil along the chain. The hypothesis behind the proposed solution and proved already experimentally on proxy and ex-vivo corneas is that the travel time of the waves is monotonically dependent to the IOP. This paper examines the effect of IOP and central corneal thickness (CCT) on the propagating waves using advanced finite element analysis with a hyper-viscoelastic model of artificial corneas. These numerical simulations validate previous experimental findings while demonstrating that the hyper-viscoelastic model provides superior accuracy when compared to an earlier linear model developed by the group, in capturing the relationships between time-of-flight, IOP, and CCT. These results advance the theoretical foundation of a new portable device that could improve glaucoma care.

Authors

Institutions

Publication Details

Journal
Journal of Applied Mechanics
Published
2026-07-23
DOI
https://doi.org/10.1115/1.4072376
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite Element Implementation, Validation, and Interpretation of a Solitary Wave Tonometer Using Hyper-Viscoelastic Corneal Models

Piervincenzo Rizzo, Ali Komaie
Journal of Applied Mechanics
Corneal surgery and disorders
article

Finite Element Implementation, Validation, and Interpretation of a Solitary Wave Tonometer Using Hyper-Viscoelastic Corneal Models

Piervincenzo Rizzo, Ali Komaie
article en

Abstract

Abstract Glaucoma is an age-related disease whose progression can be slowed by managing intraocular pressure (IOP). While Goldmann applanation remains the gold standard for IOP measurement, it provides only single-point readings that may fail to capture circadian fluctuations and sporadic pressure surges. This limitation can be addressed with a patient-operated device capable of continuous monitoring or frequent measurements anywhere, anytime. Our group has recently proposed a new tonometer based on the propagation of highly nonlinear solitary waves within a chain of particles. An incident solitary wave (ISW) is induced at one end of the chain. Once the ISW reaches the opposite end and in dry contact with the eye to be evaluated, a primary and a secondary solitary wave (PSW and SSW) rebound. The waves are detected by a sensing coil along the chain. The hypothesis behind the proposed solution and proved already experimentally on proxy and ex-vivo corneas is that the travel time of the waves is monotonically dependent to the IOP. This paper examines the effect of IOP and central corneal thickness (CCT) on the propagating waves using advanced finite element analysis with a hyper-viscoelastic model of artificial corneas. These numerical simulations validate previous experimental findings while demonstrating that the hyper-viscoelastic model provides superior accuracy when compared to an earlier linear model developed by the group, in capturing the relationships between time-of-flight, IOP, and CCT. These results advance the theoretical foundation of a new portable device that could improve glaucoma care.

Journal of Applied Mechanics
Harcum College (US)
National Science Foundation
Openalex Percentile: Top 9%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.