Development and Evaluation of a Multiplex Lateral Flow Immunoassay for Multiple Respiratory Virus Detection

Background: Simultaneous detection of influenza A virus (IAV), influenza B virus (IBV), and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for rapid differential diagnosis in febrile patients, particularly in the context of co-circulating respiratory viruses. However, conventional gold nanoparticle-based lateral flow immunoassays are limited by single-color readouts and insufficient sensitivity, restricting their multiplex detection capability. This study aimed to develop a multicolor latex-based immunochromatographic strip as a rapid, sensitive, and reliable tool for analyte detection.Methods: In this study, a multicolor latex microsphere-based immunochromatographic assay was developed for the rapid and simultaneous detection of SARS-CoV-2, IAV, and IBV antigens. Colored latex microspheres conjugated with virus-specific antibodies enabled visual differentiation of targets (SARS-CoV-2: red; IAV: blue; IBV: black). The analytical and clinical performance of the assay were systematically evaluated.Results: The assay enabled detection within 15 minutes, with a limit of detection (LOD) of 102 TCID50/mL for all three viruses. Clinical evaluation showed a sensitivity of 97.73% (215/220) and specificity of 100% (200/200) for SARS-CoV-2 detection, with an overall concordance rate of 98.81% (415/420) and a Kappa value of 0.9762 (p < 0.05), indicating excellent agreement with reference methods. Detection consistency for IAV and IBV was 100%. No cross-reactivity was observed with five common respiratory pathogens.Conclusions: This multicolor latex-based immunochromatographic strip exhibits rapid, sensitive, and reliable performance for analyte detection without requiring specialized training. It shows strong potential for home self-testing and early screening in settings where SARS-CoV-2 and influenza co-circulate.

Authors

Institutions

Publication Details

Journal
Discovery Medicine
Published
2026-07-23
DOI
https://doi.org/10.24976/discov.med.202638210.171
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Evaluation of a Multiplex Lateral Flow Immunoassay for Multiple Respiratory Virus Detection

Z B Liu, G Y Li, Luyan Fan
Discovery Medicine
Biosensors and Analytical Detection
article

Development and Evaluation of a Multiplex Lateral Flow Immunoassay for Multiple Respiratory Virus Detection

Z B Liu, G Y Li, Luyan Fan
article en

Abstract

Background: Simultaneous detection of influenza A virus (IAV), influenza B virus (IBV), and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for rapid differential diagnosis in febrile patients, particularly in the context of co-circulating respiratory viruses. However, conventional gold nanoparticle-based lateral flow immunoassays are limited by single-color readouts and insufficient sensitivity, restricting their multiplex detection capability. This study aimed to develop a multicolor latex-based immunochromatographic strip as a rapid, sensitive, and reliable tool for analyte detection.Methods: In this study, a multicolor latex microsphere-based immunochromatographic assay was developed for the rapid and simultaneous detection of SARS-CoV-2, IAV, and IBV antigens. Colored latex microspheres conjugated with virus-specific antibodies enabled visual differentiation of targets (SARS-CoV-2: red; IAV: blue; IBV: black). The analytical and clinical performance of the assay were systematically evaluated.Results: The assay enabled detection within 15 minutes, with a limit of detection (LOD) of 102 TCID50/mL for all three viruses. Clinical evaluation showed a sensitivity of 97.73% (215/220) and specificity of 100% (200/200) for SARS-CoV-2 detection, with an overall concordance rate of 98.81% (415/420) and a Kappa value of 0.9762 (p < 0.05), indicating excellent agreement with reference methods. Detection consistency for IAV and IBV was 100%. No cross-reactivity was observed with five common respiratory pathogens.Conclusions: This multicolor latex-based immunochromatographic strip exhibits rapid, sensitive, and reliable performance for analyte detection without requiring specialized training. It shows strong potential for home self-testing and early screening in settings where SARS-CoV-2 and influenza co-circulate.

Discovery MedicineVol. 38(210)
Xian Central Hospital (CN), First Hospital of Jiaxing (CN), Dian Diagnostics (China) (CN)
Openalex Percentile: Top 16%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and Evaluation of a Multiplex Lateral Flow Immunoassay for Multiple Respiratory Virus Detection — Z B Liu, G Y Li, et al. · Discovery Medicine (2026) | TGRS Research Map | TGRS