Effects of minimal, maximal and conventional footwear on whole-body and muscle metabolic power during running

Abstract The aim of this investigation was to examine running biomechanics in minimal, maximal and conventional running shoes using a musculoskeletal simulation approach to evaluate their effects on whole-body and muscle-level metabolic power. Fifteen healthy male runners completed overground trials in all three footwear conditions at a controlled speed of 4.0 m/s. Kinematic data were collected using an eight-camera motion-capture system, and ground reaction forces were obtained from an in-ground force plate. Musculoskeletal simulations quantified whole-body metabolic power as well as joint and muscle-level mechanical and metabolic outputs. Comparisons between footwear conditions were performed using linear mixed-effects models with repeated measures. Whole-body metabolic power did not differ between maximal (11.35 W/kg), minimal (11.07 W/kg) and conventional (11.26 W/kg) shoes. In contrast, joint mechanics and muscle-level energetics showed significant differences. Knee power generation and absorption were significantly greater in maximal (generation = 8.05; absorption = −18.07 W/kg) and conventional (generation = 8.20; absorption = −17.00 W/kg) footwear than in minimal (generation = 6.53; absorption = −12.81 W/kg). Ankle power generation and absorption were significantly higher in minimal footwear (generation = 15.89; absorption = −11.96 W/kg) than in conventional (generation = 14.23; absorption = −10.40 W/kg) or maximal (generation = 13.15; absorption = −9.37 W/kg) footwear. Stance-limb peak knee extensor power was higher in conventional (6.38 W/kg) and maximal (5.85 W/kg) than in minimal (5.48 W/kg) footwear. Whole-body metabolic power did not differ between footwear conditions, yet distinct changes in joint mechanics and muscle-level metabolic power were observed. In minimal footwear, these changes reflected a shift in the distribution of mechanical and metabolic work from the knee to the ankle.

Authors

Institutions

Publication Details

Journal
Comparative Exercise Physiology
Published
2026-08-20
DOI
https://doi.org/10.1163/17552559-bja10109
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of minimal, maximal and conventional footwear on whole-body and muscle metabolic power during running

Jinluan Lin, Jonathan Kenneth Sinclair
Comparative Exercise Physiology
Lower Extremity Biomechanics and Pathologies
article

Effects of minimal, maximal and conventional footwear on whole-body and muscle metabolic power during running

Jinluan Lin, Jonathan Kenneth Sinclair
article en

Abstract

Abstract The aim of this investigation was to examine running biomechanics in minimal, maximal and conventional running shoes using a musculoskeletal simulation approach to evaluate their effects on whole-body and muscle-level metabolic power. Fifteen healthy male runners completed overground trials in all three footwear conditions at a controlled speed of 4.0 m/s. Kinematic data were collected using an eight-camera motion-capture system, and ground reaction forces were obtained from an in-ground force plate. Musculoskeletal simulations quantified whole-body metabolic power as well as joint and muscle-level mechanical and metabolic outputs. Comparisons between footwear conditions were performed using linear mixed-effects models with repeated measures. Whole-body metabolic power did not differ between maximal (11.35 W/kg), minimal (11.07 W/kg) and conventional (11.26 W/kg) shoes. In contrast, joint mechanics and muscle-level energetics showed significant differences. Knee power generation and absorption were significantly greater in maximal (generation = 8.05; absorption = −18.07 W/kg) and conventional (generation = 8.20; absorption = −17.00 W/kg) footwear than in minimal (generation = 6.53; absorption = −12.81 W/kg). Ankle power generation and absorption were significantly higher in minimal footwear (generation = 15.89; absorption = −11.96 W/kg) than in conventional (generation = 14.23; absorption = −10.40 W/kg) or maximal (generation = 13.15; absorption = −9.37 W/kg) footwear. Stance-limb peak knee extensor power was higher in conventional (6.38 W/kg) and maximal (5.85 W/kg) than in minimal (5.48 W/kg) footwear. Whole-body metabolic power did not differ between footwear conditions, yet distinct changes in joint mechanics and muscle-level metabolic power were observed. In minimal footwear, these changes reflected a shift in the distribution of mechanical and metabolic work from the knee to the ankle.

Comparative Exercise Physiology
Fujian Medical University (CN), English Institute of Sport (GB), First Affiliated Hospital of Fujian Medical University (CN)
Openalex Percentile: Top 31%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.