AI-based Synthetic CT Angiography from Non-contrast CT for Cerebrovascular Disease Screening

BACKGROUND: CT angiography (CTA) is a key investigation in cerebrovascular disease. However, CTA is not always available and it also requires intravenous injection of iodinated contrast agents. It is increasingly possible to derive additional information from standard imaging sequences using Artificial Intelligence techniques. We investigated whether CTA maps could be derived from non-contrast CT (NCCT). METHODS: We conducted a retrospective, multicenter study across five Chinese hospitals, enrolling 3,709 patients who underwent head NCCT paired with CTA. The dataset encompassed three cerebrovascular conditions: intracranial aneurysms (IA), intracranial atherosclerotic stenosis (IAS), and normal intracranial arteries. We developed the Cerebrovascular CTA Generative Artificial Intelligence Model (CTA-GAI) to synthesize CTA images directly from NCCT head scans. Synthetic outputs were evaluated against five typical models using quantitative metrics and visual assessment by clinicians. We also assessed the potential clinical utility of synthetic CTA for preliminary screening and triage by evaluating its ability to distinguish diseased from normal intracranial arteries and to classify common cerebrovascular subtypes. RESULTS: CTA-GAI demonstrated consistent and robust performance across both the validation and test sets. In internal validation, synthetic CTA images achieved a mean absolute error (MAE) of 0.0416, mean squared error (MSE) of 0.0178, peak signal-to-noise ratio (PSNR) of 25.59 dB, and structural similarity index measure (SSIM) of 85.41%. Clinicians assigned an average visual quality score of 4.45 out of 5. These metrics reflect close approximation to real CTA images. Performance remained consistent across four external validation sets. In a test set of 110 patients, clinicians achieved an overall accuracy, precision, sensitivity, specificity, and F1 score of 92.7%, 97.7%, 86.0%, 98.3%, and 91.5%, in distinguishing diseased intracranial arteries. Differentiation between IA and IAS within diseased arteries reached 90.7% accuracy. CONCLUSION: CTA-GAI can synthesize CTA-like images from NCCT that show promising utility for preliminary assessment in clinical practice. These results support its potential role as a rapid, low-cost, and non-invasive tool for large-scale screening or triage of cerebrovascular diseases.

Authors

Institutions

Publication Details

Journal
International Journal of Stroke
Published
2026-07-22
DOI
https://doi.org/10.1177/17474930261473812
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AI-based Synthetic CT Angiography from Non-contrast CT for Cerebrovascular Disease Screening

Jiansong Fan, Kefei Chen, Xu Ch, Yue Wang et al.
International Journal of Stroke
Intracranial Aneurysms: Treatment and Complications
article

AI-based Synthetic CT Angiography from Non-contrast CT for Cerebrovascular Disease Screening

Jiansong Fan, Kefei Chen, Xu Ch, Yue Wang, Wang Xl, Qianwen Zhang, Jinxu Zhou, Wang Ht, Jian Zhou, B Xu, Jiahao Liao, Junsheng Chu, Xi Qiao
article en

Abstract

BACKGROUND: CT angiography (CTA) is a key investigation in cerebrovascular disease. However, CTA is not always available and it also requires intravenous injection of iodinated contrast agents. It is increasingly possible to derive additional information from standard imaging sequences using Artificial Intelligence techniques. We investigated whether CTA maps could be derived from non-contrast CT (NCCT). METHODS: We conducted a retrospective, multicenter study across five Chinese hospitals, enrolling 3,709 patients who underwent head NCCT paired with CTA. The dataset encompassed three cerebrovascular conditions: intracranial aneurysms (IA), intracranial atherosclerotic stenosis (IAS), and normal intracranial arteries. We developed the Cerebrovascular CTA Generative Artificial Intelligence Model (CTA-GAI) to synthesize CTA images directly from NCCT head scans. Synthetic outputs were evaluated against five typical models using quantitative metrics and visual assessment by clinicians. We also assessed the potential clinical utility of synthetic CTA for preliminary screening and triage by evaluating its ability to distinguish diseased from normal intracranial arteries and to classify common cerebrovascular subtypes. RESULTS: CTA-GAI demonstrated consistent and robust performance across both the validation and test sets. In internal validation, synthetic CTA images achieved a mean absolute error (MAE) of 0.0416, mean squared error (MSE) of 0.0178, peak signal-to-noise ratio (PSNR) of 25.59 dB, and structural similarity index measure (SSIM) of 85.41%. Clinicians assigned an average visual quality score of 4.45 out of 5. These metrics reflect close approximation to real CTA images. Performance remained consistent across four external validation sets. In a test set of 110 patients, clinicians achieved an overall accuracy, precision, sensitivity, specificity, and F1 score of 92.7%, 97.7%, 86.0%, 98.3%, and 91.5%, in distinguishing diseased intracranial arteries. Differentiation between IA and IAS within diseased arteries reached 90.7% accuracy. CONCLUSION: CTA-GAI can synthesize CTA-like images from NCCT that show promising utility for preliminary assessment in clinical practice. These results support its potential role as a rapid, low-cost, and non-invasive tool for large-scale screening or triage of cerebrovascular diseases.

International Journal of Stroke
Jiangnan University (CN), Second Military Medical University (CN), Capital Medical University (CN), Beijing Tian Tan Hospital (CN), Changhai Hospital (CN), 81th Hospital of PLA (CN), Air Force General Hospital PLA (CN), Wuxi People's Hospital (CN)
Openalex Percentile: Top 8%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.