Scanner‐agnostic artificial intelligence approach for fast bone scintigraphy

PURPOSE: Current bone scintigraphy protocols often demand full-count, 10-15 min scans to preserve image quality, and existing deep-learning (DL) denoisers typically need to be retrained or retuned for each camera manufacturer. We introduce a scanner-agnostic adaptive-diffusion U-Net designed to reconstruct diagnostic-grade images from half-time or half-dose acquisitions without scanner-specific retraining. METHODS: A multi-institutional retrospective set of 3635 studies from four gamma-camera models was Poisson-thinned to 10%-70% counts and partitioned for training/validation/testing. The network couples a U-Net backbone to a trainable isotropic diffusion layer. Quantitative evaluation (SSIM, PSNR, LPIPS) used 182 test scans. Prospective validation in 60 patients, including 20 studies acquired on an unseen Philips BrightView scanner not represented in the training set, was performed, and images were rated by three blinded nuclear medicine physicians on a 5-point Likert scale. Head-to-head comparisons evaluated the diagnostic fidelity of the DL approach. RESULTS: At 50% counts, DL reconstructions increased SSIM from 0.903 ± 0.045 to 0.963 ± 0.032 and PSNR from 30.50 ± 4.13 dB to 40.85 ± 4.55 dB compared with noisy images, while reducing LPIPS from 0.05 ± 0.01 to 0.03 ± 0.01 (p < 0.001). Reader studies showed that double-speed DL images achieved Likert scores comparable to standard acquisitions (4.4 ± 0.7 vs 4.5 ± 0.5), with no diagnostic discrepancies reported between DL and routine clinical images. CONCLUSION: In this multicenter, multi-vendor study, the adaptive-diffusion U-Net effectively supported half-time, and/or lower-activity whole-body bone scintigraphy protocols while preserving diagnostic integrity across scanners and avoiding scanner-specific retraining, supporting scalable, radiation-sparing clinical adoption.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2026-07-22
DOI
https://doi.org/10.1002/acm2.70709
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scanner‐agnostic artificial intelligence approach for fast bone scintigraphy

Vinícius de Oliveira Menezes, Tsang Ing Ren, Adriano Vigário, Maria Eduarda Flamini et al.
Journal of Applied Clinical Medical Physics
Medical Imaging Techniques and Applications
article

Scanner‐agnostic artificial intelligence approach for fast bone scintigraphy

Vinícius de Oliveira Menezes, Tsang Ing Ren, Adriano Vigário, Maria Eduarda Flamini, Marcos Antônio Dórea Machado, Cleiton Cavalcante Queiroz, Felipe Alves Mourato, ALLISSON FRANCISCO DE MORAIS, Antônio Augusto Silva Oliveira, Aurílio José dos Santos Filho
article en

Abstract

PURPOSE: Current bone scintigraphy protocols often demand full-count, 10-15 min scans to preserve image quality, and existing deep-learning (DL) denoisers typically need to be retrained or retuned for each camera manufacturer. We introduce a scanner-agnostic adaptive-diffusion U-Net designed to reconstruct diagnostic-grade images from half-time or half-dose acquisitions without scanner-specific retraining. METHODS: A multi-institutional retrospective set of 3635 studies from four gamma-camera models was Poisson-thinned to 10%-70% counts and partitioned for training/validation/testing. The network couples a U-Net backbone to a trainable isotropic diffusion layer. Quantitative evaluation (SSIM, PSNR, LPIPS) used 182 test scans. Prospective validation in 60 patients, including 20 studies acquired on an unseen Philips BrightView scanner not represented in the training set, was performed, and images were rated by three blinded nuclear medicine physicians on a 5-point Likert scale. Head-to-head comparisons evaluated the diagnostic fidelity of the DL approach. RESULTS: At 50% counts, DL reconstructions increased SSIM from 0.903 ± 0.045 to 0.963 ± 0.032 and PSNR from 30.50 ± 4.13 dB to 40.85 ± 4.55 dB compared with noisy images, while reducing LPIPS from 0.05 ± 0.01 to 0.03 ± 0.01 (p < 0.001). Reader studies showed that double-speed DL images achieved Likert scores comparable to standard acquisitions (4.4 ± 0.7 vs 4.5 ± 0.5), with no diagnostic discrepancies reported between DL and routine clinical images. CONCLUSION: In this multicenter, multi-vendor study, the adaptive-diffusion U-Net effectively supported half-time, and/or lower-activity whole-body bone scintigraphy protocols while preserving diagnostic integrity across scanners and avoiding scanner-specific retraining, supporting scalable, radiation-sparing clinical adoption.

Journal of Applied Clinical Medical PhysicsVol. 27(8)
Universidade Estadual de Maringá (BR), Universidade Federal de Pernambuco (BR), Complexo Hospitalar Universitário Professor Edgard Santos (BR), Centro de Estudos e Sistemas Avançados do Recife (BR), Hospital das Clínicas da Universidade Federal de Pernambuco (BR), Universidade Federal de Alagoas (BR)
Openalex Percentile: Top 8%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.