Assessment of the MIT wall-boiling model under fusion divertor relevant thermal-hydraulic conditions

The applicability of wall-boiling computational fluid dynamics models to fusion-relevant high-heat-flux cooling conditions remains uncertain. Under highly subcooled, high-velocity flow, classical Rensselaer Polytechnic Institute (RPI) type formulations have been shown to produce non-physical thermal behaviour. In the present work, a wall-flux-partitioning model developed by Massachusetts Institute of Technology (MIT) is implemented (including the modifications) within the ANSYS Fluent two-fluid framework and assessed against smooth-bore High heAt loaD tESt (HADES) experiments conducted at CEA-IRFM (Institut de recherche sur la fusion magnétique, CEA, Cadarache, France), under fusion-relevant conditions. The model is compared directly with both the classical RPI formulation and a conservative single-phase simulation, which does not consider heat transfer increase due to nucleate boiling.The MIT model, based on a bubble sliding-conduction mechanism, provides significantly improved agreement with the measured thermocouple temperatures compared with the classical RPI formulation. To the authors’ knowledge, this work represents the first independent implementation and assessment of this MIT wall-boiling model outside its original development. It is evaluated under fusion-divertor-relevant cooling conditions. Such simulations remain rare because they combine high heat flux, high liquid velocity, strong subcooling, and numerically stiff near-wall phase-change behaviour. Beyond the direct comparison with HADES experimental data, the present work also analyses model-relevant quantities, including local wall-temperature redistribution, wall heat-flux redistribution, heat-flux partitioning, and the response of the underlying boiling parameters. The results show that the implemented model behaves physically consistently and captures the main measured thermal trends substantially better than the classical RPI formulation.A sensitivity study of the main wall-boiling parameters and selected bulk-flow two-phase parameters shows that, under fusion-relevant conditions, the predicted thermal response of the MIT model is governed by several coupled closure relations. The bubble departure diameter andbubble departure freqency are highly influential, but nucleation site density, wait time, and sliding-area modelling also affect the solution. The selected bulk two-phase parameters have an insignificant direct thermal influence, but still affect numerical robustness. These results suggest that future development of fusion condition relevant boiling models should primarily target improved bubble departure diameter and bubble departure frequency closures.

Authors

Publication Details

Journal
International Journal of Heat and Mass Transfer
Published
2026-11-16
DOI
https://doi.org/10.1016/j.ijheatmasstransfer.2026.129783
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Assessment of the MIT wall-boiling model under fusion divertor relevant thermal-hydraulic conditions

M. Richou, Matej Tekavčič, Boštjan Končar, Aljoša Gajšek
2 links
International Journal of Heat and Mass Transfer
Heat Transfer and Boiling Studies
article

Assessment of the MIT wall-boiling model under fusion divertor relevant thermal-hydraulic conditions

M. Richou, Matej Tekavčič, Boštjan Končar, Aljoša Gajšek
article en

Abstract

The applicability of wall-boiling computational fluid dynamics models to fusion-relevant high-heat-flux cooling conditions remains uncertain. Under highly subcooled, high-velocity flow, classical Rensselaer Polytechnic Institute (RPI) type formulations have been shown to produce non-physical thermal behaviour. In the present work, a wall-flux-partitioning model developed by Massachusetts Institute of Technology (MIT) is implemented (including the modifications) within the ANSYS Fluent two-fluid framework and assessed against smooth-bore High heAt loaD tESt (HADES) experiments conducted at CEA-IRFM (Institut de recherche sur la fusion magnétique, CEA, Cadarache, France), under fusion-relevant conditions. The model is compared directly with both the classical RPI formulation and a conservative single-phase simulation, which does not consider heat transfer increase due to nucleate boiling.The MIT model, based on a bubble sliding-conduction mechanism, provides significantly improved agreement with the measured thermocouple temperatures compared with the classical RPI formulation. To the authors’ knowledge, this work represents the first independent implementation and assessment of this MIT wall-boiling model outside its original development. It is evaluated under fusion-divertor-relevant cooling conditions. Such simulations remain rare because they combine high heat flux, high liquid velocity, strong subcooling, and numerically stiff near-wall phase-change behaviour. Beyond the direct comparison with HADES experimental data, the present work also analyses model-relevant quantities, including local wall-temperature redistribution, wall heat-flux redistribution, heat-flux partitioning, and the response of the underlying boiling parameters. The results show that the implemented model behaves physically consistently and captures the main measured thermal trends substantially better than the classical RPI formulation.A sensitivity study of the main wall-boiling parameters and selected bulk-flow two-phase parameters shows that, under fusion-relevant conditions, the predicted thermal response of the MIT model is governed by several coupled closure relations. The bubble departure diameter andbubble departure freqency are highly influential, but nucleation site density, wait time, and sliding-area modelling also affect the solution. The selected bulk two-phase parameters have an insignificant direct thermal influence, but still affect numerical robustness. These results suggest that future development of fusion condition relevant boiling models should primarily target improved bubble departure diameter and bubble departure frequency closures.

International Journal of Heat and Mass TransferVol. 274
Javna Agencija za Raziskovalno Dejavnost RS, Euratom Research and Training Programme
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon