Liver Biopsy in Metabolic Dysfunction‐Associated Steatohepatitis Clinical Trials: Potential Pitfalls and Solutions

Liver biopsy is the reference standard for the evaluation of inflammation and fibrosis in MASH and is the primary endpoint in steatohepatitis clinical trials. An optimal liver biopsy is generally considered to be obtained with a 16-gauge needle, measure at least 2 cm in length and contain at least 10 complete portal tracts, although these features have not been prospectively validated as mandatory thresholds in MASH trials. Published clinical trials for MASH have not consistently reported sufficient details of liver biopsy quality (needle gauge, length, number of portal tracts) at baseline or post-treatment, and biopsy quality metrics are rarely reported separately by treatment arm. Placebo response rates in clinical trials for MASH varied widely (2% to 34%) and this variation could influence the outcomes of clinical trials. Future MASH trials should report biopsy quality metrics (needle gauge, core length and portal tract count) by treatment arm in supplementary appendices of those publications, treat the 16-gauge/≥ 2 cm/≥ 10 portal tract criteria as preferred acquisition standards rather than required thresholds, and may consider pre-specified sensitivity analyses restricted to biopsies meeting adequacy criteria, recognising that such exclusions may alter the disease spectrum and must be interpreted cautiously. Biopsy quality is a plausible contributor to variability in placebo responses and trial outcomes, but direct evidence that needle gauge, core length, or portal tract number independently affect histologic response rates in randomised MASH trials remains limited. As digital pathology/AI tools mature and NIT-based surrogate endpoints advance toward regulatory qualification, ensuring high quality histologic reference standards remains essential.

Authors

Institutions

Publication Details

Journal
Liver International
Published
2026-07-22
DOI
https://doi.org/10.1111/liv.70808
Primary Topic
Liver Disease Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Liver Biopsy in Metabolic Dysfunction‐Associated Steatohepatitis Clinical Trials: Potential Pitfalls and Solutions

ZACHARY D. GOODMAN, Fred Poordad, Eric Lawitz
Liver International
Liver Disease Diagnosis and Treatment
article

Liver Biopsy in Metabolic Dysfunction‐Associated Steatohepatitis Clinical Trials: Potential Pitfalls and Solutions

ZACHARY D. GOODMAN, Fred Poordad, Eric Lawitz
article en

Abstract

Liver biopsy is the reference standard for the evaluation of inflammation and fibrosis in MASH and is the primary endpoint in steatohepatitis clinical trials. An optimal liver biopsy is generally considered to be obtained with a 16-gauge needle, measure at least 2 cm in length and contain at least 10 complete portal tracts, although these features have not been prospectively validated as mandatory thresholds in MASH trials. Published clinical trials for MASH have not consistently reported sufficient details of liver biopsy quality (needle gauge, length, number of portal tracts) at baseline or post-treatment, and biopsy quality metrics are rarely reported separately by treatment arm. Placebo response rates in clinical trials for MASH varied widely (2% to 34%) and this variation could influence the outcomes of clinical trials. Future MASH trials should report biopsy quality metrics (needle gauge, core length and portal tract count) by treatment arm in supplementary appendices of those publications, treat the 16-gauge/≥ 2 cm/≥ 10 portal tract criteria as preferred acquisition standards rather than required thresholds, and may consider pre-specified sensitivity analyses restricted to biopsies meeting adequacy criteria, recognising that such exclusions may alter the disease spectrum and must be interpreted cautiously. Biopsy quality is a plausible contributor to variability in placebo responses and trial outcomes, but direct evidence that needle gauge, core length, or portal tract number independently affect histologic response rates in randomised MASH trials remains limited. As digital pathology/AI tools mature and NIT-based surrogate endpoints advance toward regulatory qualification, ensuring high quality histologic reference standards remains essential.

Liver InternationalVol. 46(8)
The University of Texas at San Antonio Health Science Center (US), Fairfax Neonatal Associates (US), Texas Liver Institute (US)
Openalex Percentile: Top 8%
Liver Disease Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.