A Modified Single Metamaterial Split-Ring Resonator for Enhanced Sensitivity

A novel microwave biosensor operating in the C-band is developed and characterised for enhanced glucose sensing applications. The sensor is based on a single metamaterial asymmetric split-ring resonator (SASR) and has been investigated in two configurations: a single semi-circular design (SASR-S) and a double semi-circular design (SASR-D). The structural modifications were introduced to enlarge the sensing area by creating two high-field hotspots, thereby increasing the interaction between the electromagnetic (EM) field and the sample, which consequently enhances the overall sensor sensitivity. The sensor is fabricated on a Rogers AD350A substrate and is optimised to detect glucose levels in a 1 µL solution applied within each semi-circle sensing region. To characterise the sensor’s enhanced sensitivity, we performed a 3D electromagnetic simulation of a small droplet positioned within a semicircular sensing region, varying the relative permittivity of the droplet from 45 to 65. The resulting shifts in resonant frequency served as a primary indicator of dielectric sensitivity. The sensor’s response was experimentally validated using a vector network analyser to measure the transmission coefficient (S21) of samples with no glucose and at glucose concentrations of 97 mg/dL to 286 mg/dL. The results demonstrate that the resonator configuration strongly influences the resonance frequency shift and sensitivity, with the SASR-D configuration being the most effective design. This has also been confirmed by measurements demonstrating a sensitivity of approximately 2.4 MHz/(mg/dL), representing an approximately two-fold improvement over the SASR-S sensor (sensitivity: 1.27 MHz/(mg/dL)) and a notable enhancement over previously reported sensors. These findings demonstrate the practical potential of the proposed sensor for blood glucose monitoring applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-07-22
DOI
https://doi.org/10.3390/s26144659
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Modified Single Metamaterial Split-Ring Resonator for Enhanced Sensitivity

Salam K. Khamas, Rola Saad, Amal Swileh
Sensors
Microwave and Dielectric Measurement Techniques
article

A Modified Single Metamaterial Split-Ring Resonator for Enhanced Sensitivity

Salam K. Khamas, Rola Saad, Amal Swileh
article en

Abstract

A novel microwave biosensor operating in the C-band is developed and characterised for enhanced glucose sensing applications. The sensor is based on a single metamaterial asymmetric split-ring resonator (SASR) and has been investigated in two configurations: a single semi-circular design (SASR-S) and a double semi-circular design (SASR-D). The structural modifications were introduced to enlarge the sensing area by creating two high-field hotspots, thereby increasing the interaction between the electromagnetic (EM) field and the sample, which consequently enhances the overall sensor sensitivity. The sensor is fabricated on a Rogers AD350A substrate and is optimised to detect glucose levels in a 1 µL solution applied within each semi-circle sensing region. To characterise the sensor’s enhanced sensitivity, we performed a 3D electromagnetic simulation of a small droplet positioned within a semicircular sensing region, varying the relative permittivity of the droplet from 45 to 65. The resulting shifts in resonant frequency served as a primary indicator of dielectric sensitivity. The sensor’s response was experimentally validated using a vector network analyser to measure the transmission coefficient (S21) of samples with no glucose and at glucose concentrations of 97 mg/dL to 286 mg/dL. The results demonstrate that the resonator configuration strongly influences the resonance frequency shift and sensitivity, with the SASR-D configuration being the most effective design. This has also been confirmed by measurements demonstrating a sensitivity of approximately 2.4 MHz/(mg/dL), representing an approximately two-fold improvement over the SASR-S sensor (sensitivity: 1.27 MHz/(mg/dL)) and a notable enhancement over previously reported sensors. These findings demonstrate the practical potential of the proposed sensor for blood glucose monitoring applications.

SensorsVol. 26(14)
University College London (GB), University of Sheffield (GB)
Openalex Percentile: Top 15%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.