Transvenous Lead Extraction in a Real-World Cohort: Clinical Characteristics, Outcomes, and Performance of the SAFeTY Score

Background/Objectives: The increasing use of cardiovascular implantable electronic devices has increased the need for transvenous lead extraction (TLE), which carries a relevant complication risk. The SAFeTY score was developed to predict procedure-related major complications. We evaluated TLE outcomes, explored associations between the SAFeTY score and retrospective endpoints, and compared conventional extraction (CE) with mechanical rotational sheath-assisted extraction (MRSE). Methods: This retrospective study included consecutive patients undergoing TLE at a tertiary center between 2015 and 2025. The SAFeTY score was calculated in patients undergoing MRSE and examined in relation to procedure-related and all-cause in-hospital mortality, significant post-procedural hemoglobin decrease, and a composite endpoint. Results: Among 314 patients, 193 (61.5%) underwent MRSE. These patients had longer cumulative lead dwell time and more previous procedures, indicating greater procedural complexity. Overall procedural success was 95.9%, procedure-related mortality was 0.3%, and all-cause in-hospital mortality was 4.8%. Exploratory unadjusted comparisons showed no significant differences between MRSE and CE in procedural success or mortality. In the MRSE group, 17.1% had a post-procedural hemoglobin decrease > 30 g/L. The SAFeTY score was not associated with procedure-related or all-cause mortality but was associated with the composite endpoint (odds ratio 1.12 per point, p = 0.025), with modest discrimination (area under the receiver operating characteristic curve [AUC] 0.59). Conclusions: TLE achieved high procedural success and very low procedure-related mortality. Because MRSE was non-randomly selected for more complex procedures, the study cannot establish equivalence or an independent effect of extraction strategy. Associations between the SAFeTY score and alternative retrospective endpoints should be considered exploratory and do not constitute validation for its original purpose.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-07-22
DOI
https://doi.org/10.3390/jcm15145745
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transvenous Lead Extraction in a Real-World Cohort: Clinical Characteristics, Outcomes, and Performance of the SAFeTY Score

Juš Kšela, Jan Prevolnik, Mark Racman, Jan Kafol et al.
Journal of Clinical Medicine
Cardiac pacing and defibrillation studies
article

Transvenous Lead Extraction in a Real-World Cohort: Clinical Characteristics, Outcomes, and Performance of the SAFeTY Score

Juš Kšela, Jan Prevolnik, Mark Racman, Jan Kafol, Aida Duric
article en

Abstract

Background/Objectives: The increasing use of cardiovascular implantable electronic devices has increased the need for transvenous lead extraction (TLE), which carries a relevant complication risk. The SAFeTY score was developed to predict procedure-related major complications. We evaluated TLE outcomes, explored associations between the SAFeTY score and retrospective endpoints, and compared conventional extraction (CE) with mechanical rotational sheath-assisted extraction (MRSE). Methods: This retrospective study included consecutive patients undergoing TLE at a tertiary center between 2015 and 2025. The SAFeTY score was calculated in patients undergoing MRSE and examined in relation to procedure-related and all-cause in-hospital mortality, significant post-procedural hemoglobin decrease, and a composite endpoint. Results: Among 314 patients, 193 (61.5%) underwent MRSE. These patients had longer cumulative lead dwell time and more previous procedures, indicating greater procedural complexity. Overall procedural success was 95.9%, procedure-related mortality was 0.3%, and all-cause in-hospital mortality was 4.8%. Exploratory unadjusted comparisons showed no significant differences between MRSE and CE in procedural success or mortality. In the MRSE group, 17.1% had a post-procedural hemoglobin decrease > 30 g/L. The SAFeTY score was not associated with procedure-related or all-cause mortality but was associated with the composite endpoint (odds ratio 1.12 per point, p = 0.025), with modest discrimination (area under the receiver operating characteristic curve [AUC] 0.59). Conclusions: TLE achieved high procedural success and very low procedure-related mortality. Because MRSE was non-randomly selected for more complex procedures, the study cannot establish equivalence or an independent effect of extraction strategy. Associations between the SAFeTY score and alternative retrospective endpoints should be considered exploratory and do not constitute validation for its original purpose.

Journal of Clinical MedicineVol. 15(14)
University of Ljubljana (SI), Ljubljana University Medical Centre (SI)
Openalex Percentile: Top 8%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.