In vivo rectal dosimeter with MRI marker

Background Hypofractionated external beam radiotherapy for prostate cancer necessitates precise rectal dose evaluation. We fabricated a radiochromic polyurethane-based in vivo rectal dosimeter with a custom MRI marker and a patient-specific applicator for in vivo dose verification (IDV) during gated MR-image guided radiotherapy (MR-IGRT). Methods The dosimeter featured a radiochromic polyurethane active layer, incorporating leucomalachite green (LMG) and tartrazine. To accommodate anatomical variations, a detachable PMMA applicator was designed in five sizes. For localization, four elastomeric materials, including two polyurethane-based and two silicone-based materials, were evaluated as candidate MRI markers. Post-irradiation fading was assessed over time to evaluate measurement stability. A dose-response calibration was performed to establish a linear relationship between net optical density (OD) and absorbed dose. Furthermore, dose uncertainty was analyzed based on the law of error propagation. For verification, in vivo measurements were conducted for two patients and compared with TPS-calculated doses. Results Vyta Flex 20 was selected as the optimal MRI marker due to its high signal intensity and ease of fabrication. Post-irradiation net OD showed a dose-dependent temporal response, and the readout time was standardized to 2 h. The dosimeter’s sensitivity was 0.00253 cGy -1 . Dose uncertainties were determined to be 2.1%, 2.0%, and 1.6% at 100, 200, and 300 cGy, respectively. In vivo verification showed mean dose differences of 3.7 ± 1.4% (95% CI, 0.1–7.3%) for patient #1 and 5.9 ± 2.1% (95% CI, 0.8–11.1%) for patient #2. Measured doses were consistently higher than TPS-calculated doses, suggesting possible contributions from localization uncertainty in high-dose-gradient regions and the material-dependent response of the radiochromic active layer. Conclusion The fabricated radiochromic dosimeter with a custom MRI marker and adjustable applicator demonstrated preliminary feasibility as a proof-of-concept system for in vivo rectal dose verification during MR-IGRT. Further studies with larger patient cohorts and more treatment fractions are required to validate its reproducibility, statistical robustness, and clinical utility. Further refinement in positioning is also needed, particularly in dose-gradient regions.

Authors

Publication Details

Journal
PLoS ONE
Published
2026-07-22
DOI
https://doi.org/10.1371/journal.pone.0354149
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vivo rectal dosimeter with MRI marker

Jin Dong Cho, Euntaek Yoon, Jong Min Park, Chang Heon Choi et al.
PLoS ONE
Advanced Radiotherapy Techniques
article

In vivo rectal dosimeter with MRI marker

Jin Dong Cho, Euntaek Yoon, Jong Min Park, Chang Heon Choi, Jeongho Kim, Jung-in Kim, Jin Ho Kim
article en

Abstract

Background Hypofractionated external beam radiotherapy for prostate cancer necessitates precise rectal dose evaluation. We fabricated a radiochromic polyurethane-based in vivo rectal dosimeter with a custom MRI marker and a patient-specific applicator for in vivo dose verification (IDV) during gated MR-image guided radiotherapy (MR-IGRT). Methods The dosimeter featured a radiochromic polyurethane active layer, incorporating leucomalachite green (LMG) and tartrazine. To accommodate anatomical variations, a detachable PMMA applicator was designed in five sizes. For localization, four elastomeric materials, including two polyurethane-based and two silicone-based materials, were evaluated as candidate MRI markers. Post-irradiation fading was assessed over time to evaluate measurement stability. A dose-response calibration was performed to establish a linear relationship between net optical density (OD) and absorbed dose. Furthermore, dose uncertainty was analyzed based on the law of error propagation. For verification, in vivo measurements were conducted for two patients and compared with TPS-calculated doses. Results Vyta Flex 20 was selected as the optimal MRI marker due to its high signal intensity and ease of fabrication. Post-irradiation net OD showed a dose-dependent temporal response, and the readout time was standardized to 2 h. The dosimeter’s sensitivity was 0.00253 cGy -1 . Dose uncertainties were determined to be 2.1%, 2.0%, and 1.6% at 100, 200, and 300 cGy, respectively. In vivo verification showed mean dose differences of 3.7 ± 1.4% (95% CI, 0.1–7.3%) for patient #1 and 5.9 ± 2.1% (95% CI, 0.8–11.1%) for patient #2. Measured doses were consistently higher than TPS-calculated doses, suggesting possible contributions from localization uncertainty in high-dose-gradient regions and the material-dependent response of the radiochromic active layer. Conclusion The fabricated radiochromic dosimeter with a custom MRI marker and adjustable applicator demonstrated preliminary feasibility as a proof-of-concept system for in vivo rectal dose verification during MR-IGRT. Further studies with larger patient cohorts and more treatment fractions are required to validate its reproducibility, statistical robustness, and clinical utility. Further refinement in positioning is also needed, particularly in dose-gradient regions.

PLoS ONEVol. 21(7)
Good health and well-being
Openalex Percentile: Top 9%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.