3D-Printed Flexible Pressure Sensors Based on Deep Eutectic Ionic Conductors for Motion Monitoring

Flexible pressure sensors have shown broad application prospects in motion monitoring, wearable healthcare, and human–machine interaction. However, conventional sensing systems that rely on rigid electronically conductive fillers to construct conductive pathways often suffer from insufficient compliance, interfacial mismatch, and limited cyclic stability. Deep eutectic solvents (DESs) are attractive candidates because of their facile preparation, tunable composition, abundant hydrogen-bonding interactions, and favorable ionic transport behavior. Hence, we propose a filler-free digital light processing (DLP)-printable ionic elastomer ink based on a pentaerythritol tetrakis(3-mercaptopropionate) (PETMP)/trimethylolpropane triacrylate (TMPTA)/epoxy resin (EP) photocurable matrix and a directly incorporated choline chloride (ChCl)/2-hydroxyethyl methacrylate (HEMA) DES ionic conductive phase. Through combined thiol-ene and thiol-epoxy click reactions, a stable elasticity-dominated network was formed, enabling the fabrication of a ring-shaped flexible pressure sensor with a rhombic pore-array structure. The optimized printable ink exhibited a low viscosity of 16.71 mPa·s and a short rheological gelation time of approximately 6.00 s in the UV-assisted rheological curing test, while the ring-shaped sensor structure could be printed within 24 min 8 s. The as-prepared sensor exhibited a broad response range of 0–281.9 kPa, fast response/recovery times of 80.5/102.4 ms, and stable cyclic performance over 2000 cycles. In addition, the device enabled glove-assisted finger-motion monitoring, discrimination of different compressive strains, and Morse-code signal recognition, indicating its potential for motion monitoring. This study provides a potential strategy for readily fabricating DLP-printable flexible deep eutectic ionic sensors.

Authors

Institutions

Publication Details

Journal
ACS Applied Polymer Materials
Published
2026-07-22
DOI
https://doi.org/10.1021/acsapm.6c02030
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D-Printed Flexible Pressure Sensors Based on Deep Eutectic Ionic Conductors for Motion Monitoring

W B Wang, Baojiang Liu, Dan Yu, Feiyue Zhou et al.
ACS Applied Polymer Materials
Advanced Sensor and Energy Harvesting Materials
article

3D-Printed Flexible Pressure Sensors Based on Deep Eutectic Ionic Conductors for Motion Monitoring

W B Wang, Baojiang Liu, Dan Yu, Feiyue Zhou, Yingtao Li, Chunyan Hu, Yuting Xue, Xueting Xu, Jieyu Zhang, Ruiyao Qin
article en

Abstract

Flexible pressure sensors have shown broad application prospects in motion monitoring, wearable healthcare, and human–machine interaction. However, conventional sensing systems that rely on rigid electronically conductive fillers to construct conductive pathways often suffer from insufficient compliance, interfacial mismatch, and limited cyclic stability. Deep eutectic solvents (DESs) are attractive candidates because of their facile preparation, tunable composition, abundant hydrogen-bonding interactions, and favorable ionic transport behavior. Hence, we propose a filler-free digital light processing (DLP)-printable ionic elastomer ink based on a pentaerythritol tetrakis(3-mercaptopropionate) (PETMP)/trimethylolpropane triacrylate (TMPTA)/epoxy resin (EP) photocurable matrix and a directly incorporated choline chloride (ChCl)/2-hydroxyethyl methacrylate (HEMA) DES ionic conductive phase. Through combined thiol-ene and thiol-epoxy click reactions, a stable elasticity-dominated network was formed, enabling the fabrication of a ring-shaped flexible pressure sensor with a rhombic pore-array structure. The optimized printable ink exhibited a low viscosity of 16.71 mPa·s and a short rheological gelation time of approximately 6.00 s in the UV-assisted rheological curing test, while the ring-shaped sensor structure could be printed within 24 min 8 s. The as-prepared sensor exhibited a broad response range of 0–281.9 kPa, fast response/recovery times of 80.5/102.4 ms, and stable cyclic performance over 2000 cycles. In addition, the device enabled glove-assisted finger-motion monitoring, discrimination of different compressive strains, and Morse-code signal recognition, indicating its potential for motion monitoring. This study provides a potential strategy for readily fabricating DLP-printable flexible deep eutectic ionic sensors.

ACS Applied Polymer Materials
Donghua University (CN)
Peace, Justice and strong institutions
Openalex Percentile: Top 16%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.