Research on the anti-pull performance of a novel small-diameter steel tube-stud grouting connector

To clarify the pull-out performance of steel tube-stud grouting (STG) connectors, this paper designed 18 test specimens, with main research parameters including embedment depth of stud (4d and 8d), steel type of stud, steel tube thickness, stud end diameter, and steel tube backing plate hole diameter. The study investigated the failure mode and deformation capacity of connectors, and strain patterns of the studs and steel tubes in the connectors, through pull-out tests and numerical simulation analysis. The study found a high degree of consistency between experimental and simulated results, and strain and stress in the studs gradually increased from the ends outward. This study fills an existing research gap regarding external-wall connections for steel structures and proposes an innovative, reliable connecting detail for prefabricated steel facade joints. Test results confirm that the proposed connection exhibits favourable pullout behaviour even with low-strength grout and a shallow stud embedment of 4d, which reduces material costs and simplifies field construction. The derived formula for yield load capacity achieves high prediction accuracy (maximum error is 11.3%) and applies to practical engineering calculations, thereby enhancing design efficiency and structural safety. In addition, this work provides theoretical underpinnings and experimental datasets for parametric optimization, engineering popularization, and the development of specifications for STG connectors.

Authors

Publication Details

Journal
PLoS ONE
Published
2026-07-22
DOI
https://doi.org/10.1371/journal.pone.0353244
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the anti-pull performance of a novel small-diameter steel tube-stud grouting connector

Jianfa Wang, Enhe Bao, Yong-Song Wu, Cheng-jun Luo et al.
PLoS ONE
Structural Load-Bearing Analysis
article

Research on the anti-pull performance of a novel small-diameter steel tube-stud grouting connector

Jianfa Wang, Enhe Bao, Yong-Song Wu, Cheng-jun Luo, Chang-jian Xiao, Ming-su Zhou
article en

Abstract

To clarify the pull-out performance of steel tube-stud grouting (STG) connectors, this paper designed 18 test specimens, with main research parameters including embedment depth of stud (4d and 8d), steel type of stud, steel tube thickness, stud end diameter, and steel tube backing plate hole diameter. The study investigated the failure mode and deformation capacity of connectors, and strain patterns of the studs and steel tubes in the connectors, through pull-out tests and numerical simulation analysis. The study found a high degree of consistency between experimental and simulated results, and strain and stress in the studs gradually increased from the ends outward. This study fills an existing research gap regarding external-wall connections for steel structures and proposes an innovative, reliable connecting detail for prefabricated steel facade joints. Test results confirm that the proposed connection exhibits favourable pullout behaviour even with low-strength grout and a shallow stud embedment of 4d, which reduces material costs and simplifies field construction. The derived formula for yield load capacity achieves high prediction accuracy (maximum error is 11.3%) and applies to practical engineering calculations, thereby enhancing design efficiency and structural safety. In addition, this work provides theoretical underpinnings and experimental datasets for parametric optimization, engineering popularization, and the development of specifications for STG connectors.

PLoS ONEVol. 21(7)
Openalex Percentile: Top 13%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on the anti-pull performance of a novel small-diameter steel tube-stud grouting connector — Jianfa Wang, Enhe Bao, et al. · PLoS ONE (2026) | TGRS Research Map | TGRS