Application of improved holographic imaging technology in prostate biopsy

Abstract Objective This study aimed to investigate whether the auto-registration feature of improved holographic imaging technology improves the accuracy and efficiency of prostate biopsy. Methods Six healthy adult male Labrador retrievers were randomized into observation and control groups. Calcium carbonate-agar composite gel was implanted into the canine prostate to create mimic lesions. In the observation group, repeat implantation at the original lesion mimic site was performed under improved holographic imaging guidance to simulate targeted prostate biopsy, while the control group underwent the same procedure using conventional holographic guidance. All animals underwent Whole-abdomen CT scans followed by prostatectomy for whole mount sections examination. The positional differences of the lesion mimics implanted twice in the prostate of the two groups of dogs in three-dimensional space were compared respectively on CT images and large tissue sections. Procedure times for repeat implantation were recorded and compared between two groups. Results On CT images and whole mount sections, the distances of the lesion mimics implanted twice in the control group along the X-axis, Y-axis, and Z-axis were 4.42 ± 1.25 mm & 4.05 ± 1.18 mm, 2.61 ± 1.15 mm & 2.44 ± 1.32 mm, and 3.88 ± 1.42 mm & 3.58 ± 1.51 mm, respectively. The observation groups were 1.94 ± 1.43 mm & 1.71 ± 1.19 mm, 1.62 ± 1.27 mm & 1.28 ± 1.33 mm, and 1.82 ± 1.35 mm & 1.57 ± 1.22 mm, respectively. Whether on CT images or whole mount sections, the distances of the lesion mimics implanted twice in the control group along the X-axis, Y-axis, and Z-axis were significantly longer than those in the observation group ( P < 0.05). The time required from the fixation of the experimental dog's position to the completion of implantation in the control group was 18.76 ± 2.59 min, while that in the observation group was 11.32 ± 1.75 min, which was significantly shorter than that in the control group ( P = 0.015). Conclusion The automatic registration function of the improved holographic imaging technology can, to a certain extent, shorten the operation time while improving the accuracy of puncture. Trial registration : CHICTR, CTR2500104865. Registered 25 June 2025. https://www.chictr.org.cn .

Authors

Publication Details

Journal
European journal of medical research
Published
2026-07-22
DOI
https://doi.org/10.1186/s40001-026-04952-2
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of improved holographic imaging technology in prostate biopsy

Chen Ji, Xue-Fei Ding, Xiao Tan, Yang Luan et al.
European journal of medical research
Digital Holography and Microscopy
article

Application of improved holographic imaging technology in prostate biopsy

Chen Ji, Xue-Fei Ding, Xiao Tan, Yang Luan, Qin Xiao, Feng-hong Cao, Sheng-ming Lu
article en

Abstract

Abstract Objective This study aimed to investigate whether the auto-registration feature of improved holographic imaging technology improves the accuracy and efficiency of prostate biopsy. Methods Six healthy adult male Labrador retrievers were randomized into observation and control groups. Calcium carbonate-agar composite gel was implanted into the canine prostate to create mimic lesions. In the observation group, repeat implantation at the original lesion mimic site was performed under improved holographic imaging guidance to simulate targeted prostate biopsy, while the control group underwent the same procedure using conventional holographic guidance. All animals underwent Whole-abdomen CT scans followed by prostatectomy for whole mount sections examination. The positional differences of the lesion mimics implanted twice in the prostate of the two groups of dogs in three-dimensional space were compared respectively on CT images and large tissue sections. Procedure times for repeat implantation were recorded and compared between two groups. Results On CT images and whole mount sections, the distances of the lesion mimics implanted twice in the control group along the X-axis, Y-axis, and Z-axis were 4.42 ± 1.25 mm & 4.05 ± 1.18 mm, 2.61 ± 1.15 mm & 2.44 ± 1.32 mm, and 3.88 ± 1.42 mm & 3.58 ± 1.51 mm, respectively. The observation groups were 1.94 ± 1.43 mm & 1.71 ± 1.19 mm, 1.62 ± 1.27 mm & 1.28 ± 1.33 mm, and 1.82 ± 1.35 mm & 1.57 ± 1.22 mm, respectively. Whether on CT images or whole mount sections, the distances of the lesion mimics implanted twice in the control group along the X-axis, Y-axis, and Z-axis were significantly longer than those in the observation group ( P < 0.05). The time required from the fixation of the experimental dog's position to the completion of implantation in the control group was 18.76 ± 2.59 min, while that in the observation group was 11.32 ± 1.75 min, which was significantly shorter than that in the control group ( P = 0.015). Conclusion The automatic registration function of the improved holographic imaging technology can, to a certain extent, shorten the operation time while improving the accuracy of puncture. Trial registration : CHICTR, CTR2500104865. Registered 25 June 2025. https://www.chictr.org.cn .

European journal of medical research
Openalex Percentile: Top 10%
Digital Holography and Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.