The trap device retrieves the detached stent that is floating within the ascending aorta

Coronary stent dislodgement is a relatively infrequent iatrogenic complication associated with percutaneous coronary intervention (PCI). It can result in severe outcomes, including vascular embolism, coronary rupture, malignant arrhythmia, and even death. We reported a patient who previously underwent stent implantation in the left anterior descending artery (LAD) and required a second-stage surgery. During the insertion of a new stent into the left circumflex artery (LCX), the guidewire passed through the mesh of the original stent. This caused the new stent to pull and deform the original stent during advancement. Consequently, the new stent dislodged, and the two stents intertwined and floated in the aorta. Eventually, the two stents were successfully removed using a stent snare, and a new stent was reimplanted in the LAD, thereby avoiding the risk of the dislodged stent falling into other arteries and causing embolism. In our case, the characteristic of the original stent protruding into the left main coronary artery (LM) and the surgeon’s failure to promptly confirm the position of the guidewire were the main causes of this incident, which provide valuable experience for future interventional surgeries. When the original stent located at the bifurcation of the blood vessel is passed through, preoperative assessment of the spatial relationship between the blood vessels, careful confirmation of the position of the guidewire, and timely analysis of whether stent dislodgement, traction, etc. occurs when advancement is impeded are critical to procedural success.

Authors

Institutions

Publication Details

Journal
Journal of Cardiothoracic Surgery
Published
2026-07-22
DOI
https://doi.org/10.1186/s13019-026-04655-z
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The trap device retrieves the detached stent that is floating within the ascending aorta

Meng Liang, Li-An Liao, Rong-tai Luo, Xin-ping Lan et al.
Journal of Cardiothoracic Surgery
Coronary Interventions and Diagnostics
article

The trap device retrieves the detached stent that is floating within the ascending aorta

Meng Liang, Li-An Liao, Rong-tai Luo, Xin-ping Lan, Hua-qing Yao
article en

Abstract

Coronary stent dislodgement is a relatively infrequent iatrogenic complication associated with percutaneous coronary intervention (PCI). It can result in severe outcomes, including vascular embolism, coronary rupture, malignant arrhythmia, and even death. We reported a patient who previously underwent stent implantation in the left anterior descending artery (LAD) and required a second-stage surgery. During the insertion of a new stent into the left circumflex artery (LCX), the guidewire passed through the mesh of the original stent. This caused the new stent to pull and deform the original stent during advancement. Consequently, the new stent dislodged, and the two stents intertwined and floated in the aorta. Eventually, the two stents were successfully removed using a stent snare, and a new stent was reimplanted in the LAD, thereby avoiding the risk of the dislodged stent falling into other arteries and causing embolism. In our case, the characteristic of the original stent protruding into the left main coronary artery (LM) and the surgeon’s failure to promptly confirm the position of the guidewire were the main causes of this incident, which provide valuable experience for future interventional surgeries. When the original stent located at the bifurcation of the blood vessel is passed through, preoperative assessment of the spatial relationship between the blood vessels, careful confirmation of the position of the guidewire, and timely analysis of whether stent dislodgement, traction, etc. occurs when advancement is impeded are critical to procedural success.

Journal of Cardiothoracic Surgery
Meizhou City People's Hospital (CN)
Good health and well-being
Openalex Percentile: Top 7%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.