Dosimetric correlation between exit dose maps and anatomical changes in head and neck cancer treatment on Halcyon‐E: A gamma analysis approach

BACKGROUND: Head and neck cancer (HNC) has a high incidence in Brazil. Although Image-Guided Radiation Therapy (IGRT) improves treatment precision, anatomical changes during the treatment course may compromise dose distribution and require replanning. PURPOSE: This study investigated the correlation between exit dose fluence and anatomical volumetric variations during HNC radiotherapy. Subsequently, a decision support methodology was proposed and validated to flag potential dosimetric deviations and guide objective replanning strategies. METHODS: A retrospective study was conducted with 11 patients, totaling 312 fractions treated on a Halcyon-E linear accelerator. Volumetric variations were derived from cone-beam computed tomography (CBCT) and exit dose fluence maps from each fraction were compared with the reference from the first treatment day using gamma analysis (γ_(1%/1 mm) to γ_(5%/5 mm); 10% threshold). Correlations between normalized volumetric variation (ΔV) and gamma indices were assessed using Kendall's tau coefficient (α = 0.05). A decision support methodology for replanning (γ_(1%/1 mm) < 80% and γ_(2%/2 mm) < 90%) was proposed and retrospectively validated in an independent cohort of 20 patients, comprising 618 treatment fractions. RESULTS: Strong negative correlations were observed between ΔV and gamma indices, with γ_(1%/1 mm) showing the highest sensitivity (τ = -0.83), followed by γ_(2%/2 mm) (τ = -0.75). Volumetric variations exceeding 5% were associated with significant dosimetric degradation. The validation correctly identified all replanned patients and detected potential indicators of dosimetric divergence not recognized in routine clinical practice. CONCLUSIONS: The thresholds γ_(1%/1 mm) < 80% and γ_(2%/2 mm) < 90%, combined with ΔV > 5%, proved effective for guiding replanning decisions. The proposed methodology demonstrated high sensitivity for detecting dosimetric deviations, with potential to enhance radiotherapy safety and effectiveness.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2026-07-22
DOI
https://doi.org/10.1002/acm2.70710
Primary Topic
Head and Neck Cancer Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric correlation between exit dose maps and anatomical changes in head and neck cancer treatment on Halcyon‐E: A gamma analysis approach

Jaime Luiz Ludwig, Jayane Julia Pereira da Silva, Ayane Cristine Alves Sarmento, Bruno Nunes Melo da Silva et al.
Journal of Applied Clinical Medical Physics
Head and Neck Cancer Studies
article

Dosimetric correlation between exit dose maps and anatomical changes in head and neck cancer treatment on Halcyon‐E: A gamma analysis approach

Jaime Luiz Ludwig, Jayane Julia Pereira da Silva, Ayane Cristine Alves Sarmento, Bruno Nunes Melo da Silva, Edilmar de Moura Santos, Caio Weber Mendanha Ribeiro, Daniela Rocha Medrado
article en

Abstract

BACKGROUND: Head and neck cancer (HNC) has a high incidence in Brazil. Although Image-Guided Radiation Therapy (IGRT) improves treatment precision, anatomical changes during the treatment course may compromise dose distribution and require replanning. PURPOSE: This study investigated the correlation between exit dose fluence and anatomical volumetric variations during HNC radiotherapy. Subsequently, a decision support methodology was proposed and validated to flag potential dosimetric deviations and guide objective replanning strategies. METHODS: A retrospective study was conducted with 11 patients, totaling 312 fractions treated on a Halcyon-E linear accelerator. Volumetric variations were derived from cone-beam computed tomography (CBCT) and exit dose fluence maps from each fraction were compared with the reference from the first treatment day using gamma analysis (γ_(1%/1 mm) to γ_(5%/5 mm); 10% threshold). Correlations between normalized volumetric variation (ΔV) and gamma indices were assessed using Kendall's tau coefficient (α = 0.05). A decision support methodology for replanning (γ_(1%/1 mm) < 80% and γ_(2%/2 mm) < 90%) was proposed and retrospectively validated in an independent cohort of 20 patients, comprising 618 treatment fractions. RESULTS: Strong negative correlations were observed between ΔV and gamma indices, with γ_(1%/1 mm) showing the highest sensitivity (τ = -0.83), followed by γ_(2%/2 mm) (τ = -0.75). Volumetric variations exceeding 5% were associated with significant dosimetric degradation. The validation correctly identified all replanned patients and detected potential indicators of dosimetric divergence not recognized in routine clinical practice. CONCLUSIONS: The thresholds γ_(1%/1 mm) < 80% and γ_(2%/2 mm) < 90%, combined with ΔV > 5%, proved effective for guiding replanning decisions. The proposed methodology demonstrated high sensitivity for detecting dosimetric deviations, with potential to enhance radiotherapy safety and effectiveness.

Journal of Applied Clinical Medical PhysicsVol. 27(8)
Liga Contra el Cancer (PE), Instituto Federal do Piauí (BR)
Good health and well-being
Openalex Percentile: Top 6%
Head and Neck Cancer Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.